Disk Configuration for Sun Blade X6250 Server ModuleCraig Winter and Dale Layfield, July 2008 Configuring Disks on the Sun Blade X6250 Server ModuleA Sun Blade X6250 Server Module holds up to four 2.5-inch SAS or SATA hard disk drives. New drives need to be set up using the RAID Configuration Utility. The following instructions assume that there are two disk drives in the Sun Blade X6250 Server Module. User input is shown in 1. Connect a keyboard, mouse, and monitor to the dongle cable that comes with the Sun Blade 6000 modular system. Plug the dongle cable into the front of the X6250 blade. 2. Power on the X6250 blade by pressing the small power button on the front of the unit. As the machine is booting, it will get to a point where it displays:
Then a prompt for the RAID Configuration Utility appears: Ctrl-A to bring up the Adaptec RAID Configuration Utility 3. Press
Sun STK RAID REM Controller #0
Options
Array Configuration Utility
SerialSelect Utility
Disk Utilities
4. Select:
The Utility comes up and the Main Menu appears:
Main Menu
Manage Arrays
Create Array
Initialize Drives
Rescan Drives
Secure Erase Drives
5. Select:
The disk drives are presented and must be selected:
Select drives for Initialization
J3 :Dev00 FUJITSU MAUZ2073RC 68.36GB
J3 :Dev01 FUJITSU MAUZ2073RC 68.36GB
6. Select:
7. Select:
Selected Drives
J3 :Dev00 FUJITSU MAUZ2073RC 68.36GB
J3 :Dev01 FUJITSU MAUZ2073RC 68.36GB
Warning: Initialization will erase any Array information.....
8. Create a storage array using the disk drives. First disk
Main Menu
Manage Arrays
Create Array
Initialize Drives
Rescan Drives
Secure Erase Drives
9. Select:
Select drives to create Array
J3 :Dev00 FUJITSU MAUZ2073RC 68.36GB
J3 :Dev01 FUJITSU MAUZ2073RC 68.36GB
10. Select:
Selected Drives
J3 :Dev00 FUJITSU MAUZ2073RC 68.36GB
Array Properties
Second disk
Main Menu
Manage Arrays
Create Array
Initialize Drives
Rescan Drives
Secure Erase Drives
11. Select:
Select drives to create Array
J3 :Dev00 FUJITSU MAUZ2073RC 68.36GB
J3 :Dev01 FUJITSU MAUZ2073RC 68.36GB
12. Select:
Selected Drives
J3 :Dev01 FUJITSU MAUZ2073RC 68.36GB
Array Properties
13. Verify the configuration and finish. <Esc> <Esc> Exit Utility? Yes
The machine reboots and both of the disks are found. The Sun Blade X6250 Server Module is now ready to have the operating system installed. For More InformationHere are additional resources: