The Message ID: SUN4-8000-0Y
indicates an internal parity error has occurred within the hostbridge.
Use the fmdump -v -u EVENT_ID command to determine
the faulty Field Replaceable Unit (FRU). As shown in the example below,
the IOBD is identified as the failing component by the FRU:
tag in the fmdump output.
fmdump -v -u f1ae0753-0981-6019-ca62-92125659ce6d
TIME UUID SUNW-MSG-ID
Dec 31 21:32:09.6466 f1ae0753-0981-6019-ca62-92125659ce6d SUN4-8000-0Y
100% fault.io.fire.asic
FRU: hc://product-id=SUNW,Sun-Fire-T200/component=IOBD
rsrc: hc:///ioboard=0/hostbridge=0/pciexrc=1
Have this information available when contacting Sun Services for a repair.
NOTE - If this message occurs on a Sun Fire T2000, it may be because
a required parameter has not been set in the /etc/system file. See the
Sun Fire T2000 Server Product Notes available at the
Sun Documentation Center
for details (enter "Sun Fire T2000 Server Product Notes" in the Search
Documentation box).