Processor
|
|
Number of processors
|
4, 8, or 12 at 1.2-GHz
|
|
|
Architecture
|
Superscalar SPARC V9, UltraSPARC III Cu architecture
|
|
|
Cache per processor
|
Level 1: Parity-protected 32-KB instruction and 64-KB data on chip (single-bit errors are corrected)
Level 2: 8-MB external cache
|
|
|
System bus
|
Sun Fireplane interconnect at 9.6 GBps, sustained
|
|
Capacity
|
|
Capacity
|
- Up to 12 UltraSPARC III processors
- Up to 96 GB of Memory
- Up to 2x73 GB Ultra160 SCSI internal disks
- 1 integrated 160MB/s Ultra3 SCSI port
- Up to 6 PCI slots
|
|
System
|
|
Main Memory
|
8 GB to 96 GB
|
|
|
I/O
|
2 integrated Gigabit Ethernet ports (66 MHz)
1 integrated 160MB/s Ultra3 SCSI port (66 MHz)
6 open 7-inch PCI slots (64 bit; one at 66 MHz, 5 at 33 MHz)
|
|
|
System controller
|
Integrated Ultra3 SCSI supports up to 15 SCSI devices
|
|
|
Internal disk
|
Two 73 GB Ultra3 SCSI internal disks
|
|
|
Removable media
|
DVD-ROM internal drive
DDS-4 tape drive (optional)
|
|
Availability
|
|
Availability
|
Dynamic Reconfiguration of CPU/memory boards, hot CPU upgrades, redundant Sun Fireplane interconnect, redundant network connections, hot-swap disks, smart fans, 2N redundant hot-swap power supplies, hardened Operating System Kernel, hardened I/O drivers, Systems Configuration Card, proactive self-diagnostics, end-to-end data integrity including ECC, and cluster support.
|
|
Resource Management
|
|
Resource Management
|
Solaris Resource Manager, Solaris Bandwidth Manager
|
|
Software
|
|
Operating System
|
Solaris 8 Operating System (2/02) or later
|
|
|
Languages
|
C, C++, Pascal, Fortran, Java
|
|
|
Networking
|
ONC/NFS, TCP/IP, SunLink OSI, X.25, DCE, NetWare
|
|
|
System monitoring
|
Sun Management Center 3.0, Solaris Management Console
|
|
|
System and network management
|
Sun Cluster, Sun OpenBoot firmware, Solaris Web Start, Solstice DiskSuite, SunScreen Secure Net, VERITAS File System, VERITAS Volume Manager, Solaris Resource Manager, Solaris Bandwidth Manager
|
|
Environment
|
|
DC power
|
-48VDC or -60VDC
|
|
|
Operating
|
5° C to 40° C (41° F to 104° F) at 5% to 85% continuous humidity; -5°C to 55°C at 5% to 90% continuous humidity for < 96 hours under the limits of Telcordia SR-3580 (NEBS) Level 3
|
|
|
Altitude
|
Up to 3,048 m (10,000 ft.)
|
|
Regulations
|
|
Regulations
|
Meets or exceeds the following requirements:
|
|
|
Safety
|
North America: UL 60950 third edition, CSA C22.2 No 60950-00 third edition
(Certified: UL and UL for Canada)
European Community: EN 60950:2000,
(Certified: UL for Germany/GS-Mark and GOST R for Russia)
Worldwide except North America: IEC 60950:1999 and CB Bulletin
(Certified: DEMKO and UL for Argentina/IRAM S-Mark)
RFI/EMI Class A: Australia/New Zealand AS/ NZ 3548, Industry Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and U.S. FCC 47CFR15.B
|
|
|
RFI/EMI FCC Immunity
|
- EN55024 (89/336/EEC)
- Telecordia GR-1089-CORE including ESD open doors (DC only)
|
|
|
Emissions
|
- CFR Title 47 FCC Part 15 including 2-in-rack
- EN 55022 (89/336/EEC) including 2-in-rack
- Telcordia GR-1089-CORE including open doors (DC only)
|
|
|
NEBS
|
- GR-1089-CORE (EMC and Electrical Safety)
- GR-63-CORE (Physical Protection)
- SR-3580 Certification Levels
|
|
Dimensions and Weight
|
|
Height
|
527 mm (20.75 in.)
12 rack units
|
|
|
Depth
|
558 mm (22 in.) excluding cable arm
|
|
|
Width
|
445 mm (17.5 in.)
|
|
|
Weight
|
110-132 kg (240-290 lb.)
|
|
Upgrades
|
|
Upgrades
|
Trade-in allowances are available for the Sun Enterprise 420R, 450, 35x0, 4x00, and Netra t 140x servers. Older Sun servers and other vendors' systems are eligible under Sun's Server Consolidation Program. For more information, contact your local Sun sales representative or authorized Sun reseller.
|