Architecture
|
|
Blade Options
|
|
|
|
Processor Options
|
Choice of:
- UltraSPARC T1 or T2
- One or two UltraSPARC IIIi at 1.1 GHz
- AMD Opteron processor, single-core: 2.2 GHz
- AMD Opteron processor, dual-core: 1.8 GHz
|
|
System Specifications
|
|
Main Memory
|
Up to eight GB using DDR-1 technology
|
|
|
Cache
|
UltraSPARC: One MB
AMD Opteron processor: One MB
|
|
|
Disk Controller
|
LSI 1064: SAS controller
|
|
|
Operating System Support
|
- Netra CT900 with CP3260 UltraSPARC T2 ATCA Blade: Solaris 10 OS
- Netra CT900 with CP3220 Opteron ATCA Blade: Solaris 10 OS, CG Linux, Microsoft Windows 2003 Advanced Server
- Netra CT900 with CP3060 UltraSPARC T1 ATCA Blade: Solaris 10 OS
- Netra CT900 with CP3020 Opteron ATCA Blade: Solaris 10 OS, MontaVista Linux, Red Hat Linux, or Windows 2003
- Netra CT900 with CP3010 UltraSPARC ATCA Blade: Solaris 9 OS or Solaris 10 OS
|
|
|
Rackmount Kits
|
19-inch
600mm ETSI
|
|
|
Network
|
Standard interfaces
Dual 10/100/1000Base-T Ethernet ports
Support for 1G or 10G switch fabric
Dual 4 Gb FC
|
|
|
System Management
|
Two system management cards: Redundant IPMI management
|
|
|
I/O Interfaces
|
Front and rear panel I/O
|
|
|
Front Panel
|
- Dual serial ports using RJ45 connectors
with Netra (Cisco) pinout on SPARC®-based
version, single serial ports on AMD Opteron
processor-based version
- Dual RJ45 jacks for 10/100Base-T Ethernet
for maintenance
- Dual PMC I/O access on the front panel,
specific I/O dependent on PMC cards used
- Dual SAS ports (SPARC-based version only)
- Recessed reset switch
- One DB15 for telecom alarm relays
|
|
|
Rear Transition Module
|
- Dual serial ports using RJ45 connectors
with Netra (Cisco) pinout
- Dual RJ45 jacks for 10/100Base-T Ethernet
for maintenance
- PMC I/O via PIM for both PMC slots
- Dual SAS ports
|
|
|
PMC Slot
|
Dual PMC I/O access on the front panel
|
|
|
Front panel LEDs
|
Blue hot-swap LED, alarm LED, operate LED
|
|
Dimensions
|
|
Height
|
12-RU (14-slot) [21-inch, 533mm]
|
|
|
Width
|
17.7-inch, 444mm
|
|
|
Depth
|
482mm
|
|
Environment
|
|
Temperature
|
Operating: 0° to 40° Celsius, -5° to 55° Celsius short-term
|
|
|
Humidity
|
Five to 85 percent RH noncondensing, five to 90 percent RH short-term
|
|
|
Seismic
|
Earthquake Zone 4, per GR63-CORE
|
|
|
Acoustic
|
ETSI sound power 72 dB declared (attended limit), per ISO 9296, 23 degrees C inlet temperature
|
|
|
Cooling
|
12° C at inlet, ambient temperatures
of 25.5° C and above. Dual redundant hotshelf
manager (SHM)
EN 300 019-2-1 Class 1.2, EN 300 019-2-2
(except rain and condensation) Class 2.3, EN
300 019-2-3 Class 3.1 (except -5° C cold start)
|
|
|
Input Power
|
-40 V DC to -72 V DC
|
|
|
Shelf Manager Carriers
|
14-slot cardcage with two shelf manager cards
|
|
Regulatory Compliance
|
|
Safety and Ergonomics
|
cUL: UL60950-1 first edition/CSA C22.2 No. 60950-1-03 CB Report: IEC 60950-1:2001 with all national differences TUV GS: EN60950-1:2000 GOST R and Russian Hygienics Argentina S-Mark
|
|
|
Regulatory Compliance
|
Class A limits, FCC CFR47 Part 15, ICES-003, EN55022 (CE), VCCI, BSMI, C-Tick, GOST, MIC
|
|
|
Immunity
|
EN55024:1998, EN300 386v1.3.1, EN61000-4- 2,-3,-4,-5,-6, -8, 11
|
|
|
Warranty
|
Standard one-year return to depot
|
|
|
Telecom Environment Certification
|
NEBS Level 3-certified
|