Sun Netra CT900 ATCA Blade Server

Netra CT900 ATCA Blade Server - Specs Bigtop
Get It

Specifications


Key Specifications

  • Choice of UltraSPARC, Intel Xeon or AMD Opteron processors
  • Choice of Solaris, Linux, or Windows operating systems
  • Mix and match processors and operating systems in the same enclosure
  • 12U rack height
Architecture
Blade Options

Processor Options Choice of:
  • UltraSPARC T1 or T2
  • Dual-socket, quad core Intel Xeon processor
  • Single-socket, dual- or quad-core AMD Opteron processor at 1.8 GHz
System Specifications
Operating System Support
  • Netra CT900 with CP3260 UltraSPARC T2 ATCA Blade: Solaris 10 OS
  • Netra CT900 with CP3250 Xeon ATCA Blade: Solaris 10 OS, CG Linux, Microsoft Windows 2003 Advanced Server
  • Netra CT900 with CP3220 Opteron ATCA Blade: Solaris 10 OS, CG Linux, Microsoft Windows 2003 Advanced Server
  • Netra CT900 with CP3060 UltraSPARC T1 ATCA Blade: Solaris 10 OS
  • Netra CT900 with CP3020 Opteron ATCA Blade: Solaris 10 OS, MontaVista Linux, Red Hat Linux, or Windows 2003

Rackmount Kits 19-inch
600mm ETSI

Network Standard interfaces
Dual 10/100/1000Base-T Ethernet ports
Support for 1G or 10G switch fabric
Dual 4 Gb FC

System Management Two system management cards: Redundant IPMI management

I/O Interfaces Front and rear panel I/O

Front Panel See switch and processor blade for details

Rear Transition Module 12 slots for ARTM/RTM

Front panel LEDs Blue hot-swap LED, alarm LED, operate LED
Dimensions
Height 12-RU (14-slot) [21-inch, 533mm]

Width 17.7-inch, 444mm

Depth 482mm
Environment
Temperature Operating: 0° to 40° Celsius, -5° to 55° Celsius short-term

Humidity Five to 85 percent RH noncondensing, five to 90 percent RH short-term

Seismic Earthquake Zone 4, per GR63-CORE

Acoustic ETSI sound power 72 dB declared (attended limit), per ISO 9296, 23 degrees C inlet temperature

Cooling 12° C at inlet, ambient temperatures of 25.5° C and above. Dual redundant hotshelf manager (SHM)

EN 300 019-2-1 Class 1.2, EN 300 019-2-2 (except rain and condensation) Class 2.3, EN 300 019-2-3 Class 3.1 (except -5° C cold start)

Input Power -40 V DC to -72 V DC

Shelf Manager Carriers 14-slot cardcage with two shelf manager cards
Regulatory Compliance
Safety and Ergonomics cUL: UL60950-1 first edition/CSA C22.2 No. 60950-1-03 CB Report: IEC 60950-1:2001 with all national differences TUV GS: EN60950-1:2000 GOST R and Russian Hygienics Argentina S-Mark

Regulatory Compliance Class A limits, FCC CFR47 Part 15, ICES-003, EN55022 (CE), VCCI, BSMI, C-Tick, GOST, MIC

Immunity EN55024:1998, EN300 386v1.3.1, EN61000-4- 2,-3,-4,-5,-6, -8, 11

Warranty Standard one-year return to depot

Telecom Environment Certification NEBS Level 3-certified