Specifications

 
   Specifications
  »   FAQ
 

No Longer Orderable
The SunFastEthernet / Single-Ended Ultra SCSI cPCI Adapter has been retired and is no longer orderable.

Network Interfaces
10/100 Mbps Ethernet and an ultra wide SCSI adapter provides two different types of interfaces in one cPCI slot.
Ethernet
100BASE-TX transfer rate: <=100 Mbps (in each direction for full duplex)
10BASE-T transfer rate: <=10 Mbps (in each direction for full duplex) RJ45 UTP connector
SCSI
SCSI synchronous transfer rate: 20/40 MB/sec.
SCSI asynchronous transfer rate: Max. 12 MB/sec. 16-bit Max. 6 MB/sec. 8-bit
SCSI interface: Single-ended
SCSI bus parity
SCSI 8-bit bus devices
SCSI 16-bit bus devices
2-millimeter pin pitch connector SCSI

Back to Top

 
cPCI Bus Interface
cPCI clock: 33Mhz
cPCI data burst transfer rate: 132 MB/sec. (32-bit wide)
cPCI data/address lines: AD31-0
cPCI modes: Master/slave

Back to Top

 
Requirements
Available cPCI slot in a Sun Fire[tm] 3800, 4800, 4810 or 6800 server.

Back to Top

 
Dimensions
Length
160 mm
Width
100 mm
Height
(not including PCB)
Primary component side: 13.40 mm (max.)
Back component side
1.52 mm (max.)
Weight
184.27 grams

Back to Top

 
Power Consumption
Sun 10/100 Ethernet + SCSI 3U cPCI Adapter: Maximum power consumption: 10 Watts
5v (+5/-3%) supply current 1.15 A typical 50 mV
3.3v (+5/-3%) supply current 0.24 A typical 50 mV
+12v (+/-5%) supply current 10 mA max. 240 mV

Back to Top

 
Environment
Temperature: 0 to 55 degrees C (+32 to +131 degrees F)
-40 to 75 degrees C (-40 to +149 degrees F)
Relative humidity: 5 to 95% non-condensing
(45 degrees C, wet bulb temperature)
0 to 95% non-condensing
10 degrees C/hour
Altitude: -1000 to +15,000 ft.
-1000 to +50,000 ft.
Shock: 10g, 1/2 sine wave, 11 msec.
60g, 1/2 sine wave, 11 msec.
Vibration, peak to peak displacement: 0.005 in. max. (5 to 32 Hz)
0.1 in. max. (5 to 17 Hz)
Vibration, peak acceleration: 0.25g (5 to 500 Hz)
(Sweep rate = 1 octave/min.)
0.25g (5 to 500 Hz)
(Sweep rate = 1 octave/min.)

Back to Top

 
Regulations
Meets or exceeds the following requirements:
EMC: Complies with the following requirements of the EMC Directive 89/336/EEC:
EN55022:1995/CISPR22:1997 Class A
EN55024:1998:
EN61000-4-2 4 kV (Direct), 8 kV (Air)
EN61000-4-3 3 V/m
EN61000-4-4 1.0 kV Power Lines, 0.5 kV Signal Lines
EN61000-4-5 1 kV Line-Line, 2kV Line-Gnd Power Lines
EN61000-4-6 3 V
EN61000-4-8 1 A/m
EN61000-4-11 Pass
EN61000-3-2:1995 Pass
EN61000-3-3:1995 Pass

Safety: Complies with the following requirements of Low Voltage Directive 73/23/EEC: EC Type Examination Certificates: EN60950:1992,2nd Edition

Supplementary Information: Tested and complies with all the requirements for the CE Mark

Back to Top