Specifications
Offered with Solaris x86 support, Sun Dual Gigabit Ethernet + Dual SCSI PCI Adapters offer server-to-storage connectivity via 80MB/s wide ultra2 LVD/SE SCSI interfaces. LVD SCSI gives you the benefit of longer cable lengths. And, it complies with the IEEE 802.3, 802.1Q VLAN, 802.1P/802.1D Ethernet standards.
Key Specifications
-
PCI Bus: Two 10/100/1000 Base-T copper Ethernet ports and two 80MBps Wide Ultra2 SCSI connections in a single PCI slot
-
Ethernet: 10/100/1000 Mbps: IEEE 802.3 , 802.1D, Q
-
SCSI :
- SCSI synchronous transfer rate: 2 x 80 MB/sec, Wide Ultra 2
- SCSI asynchronous transfer rate: maximum 12 MB/sec (16-bit) maximum 6 MB/sec (8-bit)
- Data burst size: maximum 4 GB
- SCSI interface: single-ended (SE)/ Low Voltage Differential (LVD)
- SCSI bus parity: Yes
- SCSI 8-bit bus devices: Yes
- SCSI 16-bit bus devices: Yes
- Maximum number of devices per port: 15
-
Ethernet: Two RJ45 connectors to Cat 5, 4 pair for 1000 Mbps or better
-
SCSI: Two 68-Pin SCSI VHDCI female external connectors
|
|
|
PCI Bus
|
|
Note
|
Two 10/100/1000 Base-T Copper Ethernet Ports and two 80MBps Wide Ultra2 SCSI Connections in a Single PCI slot
|
|
|
PCI Bus
|
- PCI Rev 2.2, 32/64 bit, 33/66 MHz
- Master/slave modes
- Hot Plug capable
- 3.3 V and 5 V signaling
|
|
Standard/Integrated Interfaces
|
|
Ethernet
|
10/100/1000 Mbps: IEEE 802.3 , 802.1D, Q
|
|
|
SCSI
|
- SCSI synchronous transfer rate: 2 x 80 MB/sec, Wide Ultra 2
- SCSI asynchronous transfer rate: Maximum 12 MB/sec. (16-bit) Maximum 6 MB/sec. (8-bit)
- Data Burst size: Maximum 4 GB
- SCSI interface: Single-ended (SE)/ Low Voltage Differential (LVD)
- SCSI bus parity: Yes
- SCSI 8-bit bus devices: Yes
- SCSI 16-bit bus devices: Yes
- Maximum number of devices per port: 15
|
|
Connections
|
|
Ethernet
|
Two RJ45 connectors to Cat 5, 4 pair for 1000 Mbps or better
|
|
|
SCSI
|
Two 68-Pin SCSI VHDCI female external connectors
|
|
Operating Distance
|
|
Ethernet
|
Up to 100 meters
|
|
|
SCSI
|
- X1134A, 530-2452-02, (CBL, Ultra SCSI-3/VHDCI, 68P, 0.8m)
- X3832A, 530-2453-02, (CBL, Ultra SCSI-3/VHDCI, 68P, 2m)
- X3830A, 530-2454-02, (CBL, Ultra SCSI-3/VHDCI, 68P, 4m)
- X3831A, 530-2455-02, (CBL, Ultra SCSI-3/VHDCI, 68P, 10m)
|
|
Processor Recommendation
|
|
Note
|
Sun recommends 1MHz of CPU power per 1 Mbps data throughput. For example, to support two 1000 Mbps Ethernet connections, a system with two 1 GHz CPUs is recommended. A Sun Dual Gigabit Ethernet + Dual SCSI PCI Adapter requires an available PCI or PCI-X slot.
|
|
Software
|
|
Supported Software
|
- OS: Solaris SPARC 8 update 7 and higher
- Solaris x86 9 update 6 and higher
- Firmware OpenBoot: PROM 3.0 and higher
- Diagnostic SunVTS: 4.4 and higher
|
|
Platforms
|
|
Supported Platforms
|
- Sun StorEdge 3310 SCSI
- Netra S1 Thin Storage
- Sun StorEdge D240 Media Tray
- Sun StorEdge 3310 SCSI Array
|
|
|
System Platforms
|
- Ultra - 30, 60, 80
- Sun Blade - 100, 150, 1000, 2000, 1500, 2500 Workstations
- Netra - T1, 1125, 1405, 20, 240 servers
- Enterprise - 210, 240, 220R, 420R servers
- Sun Fire 250, 450, 280R, 480R, 880R, 440, 1280 servers
- Sun Fire - 4800, 6800 midrange servers
- Sun Fire - E2900, E4900, 6900 midrange servers
- Sun Fire - E20K, E25K high-end servers
- Sun Fire 12K, 15K high-end servers (support scheduled for CYQ2 2004)
- Sun Fire V20z, V40z servers
|
|
Environment
|
|
Operating Temperature
|
0º C to 55º C
|
|
|
Storage Temperature
|
-40º C to 85º C
|
|
|
Relative Humidity
|
0% to 95%, noncondensing
|
|
Shock and Vibration
|
|
Operating Shock
|
2.5 G, 11 msec., 1/2 sine
|
|
|
Storage Temperature
|
3.5 G, 11 msec, 1/2 sine, 4 face
|
|
|
Operating Vibration
|
0.25 G, 5 to 500 Hz
|
|
|
Nonoperating Vibration
|
0.6 G, 5 to 500 Hz
|
|
Power
|
|
Max Power Consumption
|
16.65 W
|
|
Dimensions
|
|
Length
|
175 mm (6.8 in)
|
|
|
Width
|
107 mm (4.2 in)short PCI Adapter
|
|
Certifications
|
|
Safety
|