Sun Secure Application Switch N1000 Series

Specifications


Key Specifications

  • As many as 10 virtual switches per N1400V or N1216V system
  • High volume, hardware-accelerated SSL
  • Client persistence with decrypted cookie data
  • Layer 4 through Layer 7 Gigabit application switching and load balancing with hardware-based TCP termination
  • Support for full suite of traditional load-balancing algorithms
Switching
Sun N1400/N1400V Sun N1216/N1216V
Virtual Switching
  • As many as 10 virtual switches per system
  • Dynamic allocation of switch resources into secure partitions
Performance
Sun N1400/N1400V Sun N1216/N1216V
Throughput
  • As fast as 3 Gbps application switching throughput
  • As fast as 2 Gbps cryptographic throughput
Acceleration
Sun N1400/N1400V Sun N1216/N1216V
SSL Acceleration
  • Up to 2 Gbps symmetric key SSL cryptographic throughput
  • Up to 12,500 new connections per second
  • Up to 240,000 concurrent connections
  • SSL 3.0, TLS 1.0 protocol support
  • Client-side and server-side support
  • Re-encryption for end-to-end security
  • X.509 certificate support
Management
Sun N1400/N1400V Sun N1216/N1216V
Management Methods
  • SNMPv1/v2c/v2
  • HTML and Telnet
  • Configuration logging
  • Multiple images
  • Multiple syslog servers
Traffic Management
Sun N1400/N1400V Sun N1216/N1216V
Application Switching and Load Balancing
  • As fast as 3 Gbps application switching throughput
  • As many as 56,000 Layer 7 connections per second
  • As many as 125,000 new Layer 4 through Layer 7 connections per second
  • As many as 875,000 concurrent Layer 4 through Layer 7 connections
  • Bi-directional application switching on HTTP header, URI, cookie, payload, and content
  • Client stickiness through switch-managed cookies and the client source address and port
  • Load balancing algorithms: weighted source address hash, weighted random distribution, round robin, least connections, and weighed least connections, where weighting can be statically assigned or dynamically adjusted based on real-time measurements of response times
  • Load balancing of devices transparent to participating end systems (caches and proxies)
  • Bridge mode load balancing is supported for noninvasive Layer 3 drop-in deployments
System Interfaces
Sun N1400/N1400V Sun N1216/N1216V
Networking
  • 4 SFF pluggable GbE ports
  • 2 SFF pluggable GbE ports, 16 copper 10/100Base-T ports

Network Management DB-9 serial port, RJ-45 10/100 Ethernet port
Power
Sun N1400/N1400V Sun N1216/N1216V
Input Current
  • 5.4 A at 115 VAC
  • 2.7 A at 230 VAC
  • 90 to 135/180 to 265 VAC automatic select
  • 47 to 63 Hz
Environment
Sun N1400/N1400V Sun N1216/N1216V
Operating Environment
  • Operating temperature: -32° to 104° F (0° to 40° C)
  • Storage temperature: -22° to 17, 6° F (-30° to 80° C)
  • Operating humidity: 0% to 95% relative humidity, non-condensing
  • Maximum heat dissipation: 2050 BTU/hr, fully populated
Regulations
Sun N1400/N1400V Sun N1216/N1216V
Meets or exceeds these requirements
  • FCC Part 15, Subpart B, Class A limits
  • Industry-Canada ICES-003, Class A limits
  • VCCI Class A
  • EN 60950, EN 55022 Class A
  • EN 55022: 1998/CISPR-22 Class A
  • CE: UL60950 UL/CUL
  • IEC60950
  • CSA-C22.2
  • EN55024:1998
Dimensions
Sun N1400/N1400V Sun N1216/N1216V
Height 4.45 cm (1.75 inches)

Width 44.2 cm (17.4 inches)

Depth 66.04 cm
(26 inches)
71.12 cm
(28 inches)

Weight 9.07 kg (20 lbs)

Enclosure Fits into a 1RU, two- or four-post, standard EIA/NEMA rack
Warranty
Sun N1400/N1400V Sun N1216/N1216V
Warranty Details
  • Duration: One-year parts exchange
  • Hardware onsite coverage hours: Not applicable
  • Hardware response times: 15 day parts exchange
  • Delivery method: Return to Sun
  • Hardware phone coverage: Monday – Friday, 8 am To 5 pm
  • Hardware phone response time: Eight business hours