Sun Blade 6000 Chassis
|
|
Form Factor
|
10 Rack units high, (10U), holding up to ten server modules per chassis. Up to 4 Sun Blade 6000 Chassis are supported per 42U rack.
|
|
|
I/O Interfaces
|
The Sun Blade 6000 midplane supports the following protocols: PCI Express, Gigabit Ethernet InfiniBand and SAS. Each server module has a direct connection to two PCIe ExpressModules for discrete I/O connectivity and two PCIe Network Express Modules for aggregate I/O connectivity.
|
|
I/O Modules
|
|
PCIe ExpressModules
|
Up to two per blade and total of 20 per Sun Blade 6000 Chassis
- 1 Gigabit Ethernet dual-port PCIe ExpressModule — Fiber (Intel 82571EB GbE Controller-based)
- 1 Gigabit Ethernet quad-port PCIe ExpressModule — Copper (Intel 82571EB Controller-based)1
- 1 Gigabit Ethernet quad-port PCIe ExpressModule — Copper (Sun Neptune)
- 10 Gigabit Ethernet dual-port PCIe ExpressModule — Fiber (Sun Neptune)
- 10 Gigabit Ethernet dual-port PCIe ExpressModule — Fiber (Intel 82598EB)
- Sun StorageTek dual-port 4 Gb/s Fibre Channel, dual-port GbE combination (Emulex)
- Sun StorageTek dual-port 4 Gb/s Fibre Channel, dual-port GbE combination (QLogic)
- 4 Gbps Fibre Channel dual-port PCIe ExpressModule (Qlogic ISP2432 FC Controller-based)
- 4 Gbps Fibre Channel dual-port PCIe ExpressModule (Emulex Zephyr IOC FC Controller-based)
- 4x InfiniBand SDR dual-port PCIe ExpressModule (Mellanox MT25208 InfiniHost III Ex Controller-based)
- Sun dual-port DDR InfiniBand ExpressModule (Mellanox ConnectX)
- Sun PCIe dual-port Quad Data Rate InfiniBand ExpressModule (Mellanox ConnectX)
- Sun StorageTek dual-port SAS ExpressModule
|
|
|
Network Express Modules
|
Up to two per Sun Blade 6000 Chassis
- GbE 10-port passthru NEM
- Sun Blade 6000 10 GbE multifabric NEM
- Sun Blade 6000 multifabric NEM
- Sun Blade 6000 10 GbE Virtualized NEM 10-port 1 GbE + 4-port SAS + 2 port
For the latest information on I/O module choices, go to: http://www.sun.com/servers/blades/iomodules.
|
|
Manageability
|
|
Chassis Monitoring Module (CMM)
|
Chassis Monitoring Module (CMM):
- Enables direct connection to the Service Processor on each Blade Server
- Reduces cabling by providing a single management connection to the chassis
- Ensures complete lights-out manageability of the whole chassis
- Provides an optional aggregate point for monitoring of chassis fans, power supplies with its own Sun Integrated Lights Out Management (ILOM) module
|
|
Environment
|
|
Operating temperature
|
5°C to 32°C ( 41°F to 90°F)
|
|
|
Nonoperating temperature
|
-40°C to 65°C (-40°F to 149°F)
|
|
|
Operating optimum ambient temperature
|
22°C (71.6 °F)
|
|
|
Operating Relative Humidity
|
10 to 90 percent RH, noncondensing, 27°C max. wet bulb
|
|
|
Nonoperating Relative Humidity
|
5 to 93 percent RH, noncondensing, 38°C max. wet bulb
|
|
|
Operating altitude
|
Up to 3,048m (10,000 ft.), maximum ambient temperature is derated by 1°C per 300m
(984 ft.) above 900m (2,953 ft.)
|
|
|
Nonoperating altitude
|
Up to 12,000m (39,370 ft.)
|
|
|
Operating Sine Vibration
|
Z (vertical) axis: 0.15G
X/Y axis: 0.10G
5 to 500 Hz sine
|
|
|
Nonoperating Sine Vibration
|
Z (vertical) axis: 0.50G
X/Y axis: 0.25G
5 to 500 Hz sine
|
|
|
Shock
|
3Gs, 11msec, half sine
(rackmounted enclosure)
|
|
|
Acoustics
|
LwAd (1 B=10 dB) 8.6 B at or below
25°C, 9.2 B at maximum ambient
|
|
AC Input Power
|
|
Power
|
Power (1+1) high-efficiency, hot-swappable, load-sharing, load-balancing power
supplies
|
|
|
AC Input Power
|
1+1 PSU rating, 6272 W, or 6400 VA each power supply module
|
|
|
Voltage
|
200 to 240 VAC
|
|
|
Frequency
|
50 to 60 Hz
|
|
|
Current
|
16A per power supply input, total four AC inputs (two per power supply module)
|
|
|
AC Input Connection
|
Americas Domestic - NEMA L6-20P to IEC320-C19
International - IEC309 250V, 3A, 3 Pin to IEC320-C19
|
|
DC Output Power
|
|
DC Output Power
|
1+1 PSU rating: 5600 W each power supply module
|
|
Regulations (meets or exceeds the following requirements)
|
|
Product Safety
|
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB scheme with all country differences, IEC825-1, 2, CFR21 part 1040, CNS14336, GB 4943
|
|
|
RFI/EMI (Class A)
|
EN55022, 47 CFR 15B, ICES-003, VCCI, AS/NZ 3548, CNS 13438, KSC 5858, GB 9254, EN61000-3-2, GB 17625.1, EN61000-3-3, EN300-386: v1.3.3
|
|
|
Immunity
|
EN55024, EN300-386: v1.3.3
|
|
Certifications
|
|
Product Safety
|
cULus Mark, UL/Demko LVD, CE Mark (2006/95/EC), GOST R, BSMI
|
|
|
RFI/EMI (Class A)
|
CE Mark (89/336/EEC), FCC, ICES-003, VCCI, C-Tick, MIC, GOST R, BSMI
|
|
|
Immunity
|
CE Mark (89/336/EEC), MIC, GOST R
|
|
|
Other
|
Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive, China RoHS Mark
|
|
Chassis and Components Physical Specifications
|
|
Chassis height
|
17.25 inches (438.15 mm)
|
|
|
Chassis depth
|
27.25 inches (692.15 mm)
|
|
|
Chassis width
|
17.50 inches (444.50 mm)
|
|
|
Chassis weight of a fully configured system
|
350 lb (159 kg)
|
|
|
Chassis weight of an empty system (No fillers)
|
78.7 lb (35.7 kg)
|
|
|
Subassembly weights
|
- Power Supply Module: 21.38 lb (9.70 kg)
- Network Express Module: 3.85 lb (1.75 kg)
- PCIe ExpressModule: 0.90 lb (0.41 kg)
- Rear Fan Module: 2.31 lb (1.04 kg)
- Chassis Monitoring Module: 1.15 lb (0.52 kg)
- Front Fan Module: 1.95 lb (0 .88 kg)
- Front Indicator Module: 0.75 lb (0.34 kg)
|