The Sun Blade 6048 modular system gives you up to 48 hot-pluggable server modules in a specially designed unibody chassis/rack. Each rack contains four shelves, each of which can hold up to twelve server modules, plus modular I/O, networking, system management, power supply and fan modules. It weighs less and saves space, and it's an incredible advancement in scalability, flexibility, compute and I/O density.
Key Specifications
Up to 48 Sun Blade 6000 family server modules: AMD Opteron, Intel® Xeon®, and Sun UltraSPARC
Passive midplane for ultra high-speed interconnects such as Quad Data Rate InfiniBand
Eight 5600 - 8400W power supply modules
96 PCIe (1.1 and 2.0) ExpressModule (EM) slots and 32 redundant rear fan modules
Eight Network Express Module (NEM) slots and Four Chassis Monitoring Modules (CMM)
Each installed server module has a direct connection to two PCIe ExpressModules for discrete I/O connectivity, and up to two NEMs for aggregate I/O connectivity
I/O Modules
ExpressModules
Up to 24 ExpressModules per shelf, 96 per chassis:
One per shelf, four per Sun Blade 6048 modular system:
Facilitates remote connection to the service processor on each server module
Consolidates cabling by providing a single management connection per shelf
Helps ensure complete remote lights-out manageability of the whole chassis
Provides an optional aggregate point for monitoring of chassis fans and power supplies with the CMM's own ILOM module
Environment
Operating Temperature
5° to 32° C (41° to 90° F)
noncondensing
Optimum (Operating) Ambient Temperature
23° C (73.4° F)
Nonoperating Temperature
-40° to 65° C (-40° to 149° F)
noncondensing
Operating Humidity
10–90 %
relative humidity,
noncondensing,
27° C max. wet bulb
Optimum (operating) Humidity
45–50% relative humidity,
noncondensing
Nonoperating Humidity
5–93 % relative humidity;
noncondensing,
38° C max. wet bulb
Operating Altitude
0–3,048m (0–10,000 ft.);
maximum ambient
temperature is
derated by 1° C per
300m (984 ft.) above
900m (2,953 ft.)
Nonoperating Altitude
0–12,000m (0–39,370 ft.)
Operating Sine Vibration
Z (vertical axis): 0.15 G
X/Y axis: 0.1G, 5-500 Hz sine
Nonoperating Sine Vibration
Z (vertical axis): 0.5 G
X/Y axis: 0.25G, 5-500 Hz sine
Operating Shock
3 Gs 11 msec, half sine
AC Power
Power Supply Modules
Eight per chassis
(two per shelf) —
high-efficiency, hot-swappable,
1 + 1
redundant, load balancing
8,400 W Configuration
AC Power:
1+1 PSU rating;
9,408W or 9600VA (each power supply module)
8400W DC Out Power (three 2,800W cores, all 24 AC inputs used)
5,600 W Configuration
To configure 5,600W DC Out Power (two 2,800 W cores) 16 AC inputs are used (4 per shelf)
Voltage
200–240 V AC
Frequency
50–60 Hz
Current
16A per input
AC Input Connections
Americas/domestic -
NEMA L6-20P to
EC320-C19M;
international -
IEC309 to IEC320-C19
Regulations (meets or exceeds the following requirements)
Safety
UL approved to UL 60950 and
C22.2 No. 60950, UL Demko approval to
EN60950-1 and CB , Report IEC 950 Third
Edition; including all amendments and full
worldwide deviations, GOST Certification
for Russia, Korean MIC Certification, China
CCC Mark for power supply (system is
exempt, since it is rated greater than 1,300
W), CE Declaration of Conformity to The
Electromagnetic Compatibility Directive
and Low Voltage Directive 2006/95/EC,
IRAM S-Mark for power supply (system is
exempt, due to class of equipment), CNS
14336 (Taiwan)
Laser Product and Optical I/O:
FCC registration
to Code of Federal Regulations 21 CFR
1040-Lasers, TUV approval to IEC 60825-1
Safety of Laser Products, Canadian Radiation
Emitting Devices Act REDR C1370
Electromagnetic Interference
CFR 47 Part
15 (Code of Federal Regulations, Part 15,
Subpart B) Class A, EN55022:2006 Class A
per EMC Directive 2004/108/EEC (CE
Mark), VCCI Class A, Industry Canada
ICES-003, AS/NZ 3548 (Australia/New
Zealand), CNS 13438 (Taiwan)
Immunity
EN55024:1998 +A1:2001
+A2:2003 per EMC Directive 2004/108/
EEC, including: IEC 61000-4-2 Electrostatic
discharge immunity test, IEC 61000-4-3 Radiated,
radio-frequency, electromagnetic
field immunity test, IEC 61000-4-4 Electrical
fast transient/burst immunity test,
IEC 61000-4-5 Surge immunity test, IEC
61000-4-6 Immunity to conducted disturbances,
induced by radio-frequency fields,
IEC61000-4-8 Power frequency magnetic
field immunity test, IEC 61000-4-11 Voltage
dips, short interruptions, and voltage
variations immunity tests