Performance data
|
|
Processor
|
One dual core Next-Generation AMD Opteron model 1200 Series (models 1220
(2.8 GHz), 1218 (2.6 GHz), 1210 (1.8 GHz))
|
|
|
Memory
|
Up to 8 GB; 4 DIMM slots, DDR2/667 Unbuffered ECC DIMMs (128 bit plus ECC databus), 512 MB, 1 GB, 2 GB DIMMs supported, installed in pairs
|
|
|
Networking
|
Four Integrated 10/100/1000Base-T Ethernet ports
|
|
|
PCI Slots
|
2x 8-lane PCI-Express
|
|
Mass Storage
|
|
Internal disk
|
Up to two hot-pluggable 3.5" SATA II or SAS disk drives;
250 GB, 500 GB 7200 rpm SATA II or 146 GB 15K rpm SAS supported
|
|
|
Removable Media
|
Up to one EIDE DVD-ROM or DVD+/-RW DL drive
|
|
|
RAID
|
RAID 0/1/0+1 with optional 4-port SAS HBA; all supported operating systems with pair of SATA II or SAS drives
|
|
|
External Storage
|
Supported Storage
|
|
|
Option Cards
|
Sun has interoperability tested and supports a full suite of 4 GB and 2 GB Host Bus Adapters (HBAs). These HBAs offer unique features and benefits including Solaris integration and heterogeneous OS support. In the case of a Solaris environment, Sun HBAs combined with Sun Solaris OS provide the fastest, most reliable failover, highest availability, increased performance and dynamic load balancing by utilizing the Solaris SAN Foundation Suite drivers.
|
|
Software
|
|
Operating Systems
|
Solaris OS, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, and Microsoft Windows. See supported Operating Systems.
|
|
|
Languages
|
C/C++, FORTRAN (Solaris 10 OS), the Java programming language, all other standard Sun-supported languages
|
|
|
Networking
|
ONC, ONC+, NFS, WebNFS, TCP/IP, SunLink software, OSI, MHS, IPX/SPX, SMB technologies, XML
|
|
|
Management
|
Service processor with embedded Lights Out Management (LOM) standard.
Provides IPMI 2.0 in-band and out-of-band management.
Service processor is functionally equivalent to the ILOM used in the Sun Fire X4100 and X4200 servers.
See the Embedded Lights Out Manager Adminstration Guide
|
|
Management
|
|
Feature
|
Standard Service Processor
with embedded LOM
|
|
|
Remote Power/power cycle systems
|
Yes
|
|
|
Monitor key system components (CPU, Voltages, Chassis temperature, fans)
|
Yes
|
|
|
Comprehensive hardware monitoring
|
Yes
|
|
|
DMTF SMASH CLI command set
|
Yes
|
|
|
Serial & Network Access
|
Yes
|
|
|
Dedicated Management Port
|
Yes
|
|
|
Serial-Over-LAN support (SOL)
|
Yes
|
|
|
SSH support
|
Yes
|
|
|
Console Redirection
|
Yes
|
|
|
Comprehensive Browser interface
|
Yes
|
|
|
Remote KVM
|
Yes
|
|
|
Remote Media capability (DVD, CD, Floppy)
|
Yes
|
|
|
Simple GUI or CLI driven BIOS and firmware upgrade procedure
|
Yes
|
|
|
IPMI support
|
IMPI v2.0
|
|
|
SNMP support
|
Yes
|
|
Environmental
|
|
Operating temperature (single, non-rack system)
|
5° C to 35° C (41°F to 95° F), 10% to 90% relative humidity, non-condensing, 27° C max wet bulb
|
|
|
Nonoperating temperature (single, non-rack system)
|
-40 C to 65° C (-40° F to 149° F), up to 93% relative humidity, non-condensing, 38° C max wet bulb
|
|
|
Altitude (operating) (single, non-rack system
|
Up to 3,000 m, maximum ambient temperature is derated by 1° C per 300 m above 500 m
|
|
|
Altitude (nonoperating) (single, non-rack system)
|
Up to 12000 m
|
|
Power
|
|
Quantity of Power Supplies
|
One
|
|
|
Power Supply UL Maximum (AC input)
|
6.5 Amps
|
|
|
Power Supply Rating (DC output)
|
345 Watts
|
|
|
In Use System Power
|
See the X2100 Power Calculator
|
|
Dimensions and Weight
|
|
Height
|
43 mm (1.7")
|
|
|
Width
|
425.5mm (16.8")
|
|
|
Depth
|
633.7 mm (25")
|
|
|
Weight (Maximum)
|
10.7 kg (23.45 lbs)
|
|
Mounting Options
|
|
Mounting Options
|
- 19-inch rackmount kit
- Express 19-inch rackmount kit (tooless)
|
|
Documentation
|
|
Product Documentation
|
Latest Documents
- Where to Find Sun Fire X2100 M2 Server Documentation
- Sun Fire X2100 M2 Server Product Notes
- Sun Fire X2100 M2 Server Operating System Installation Guide
- Embedded Lights Out Manager Adminstration Guide (X2100 M2)
- Sun Fire X2100 M2 Server Installation Guide
- Sun Fire X2100 M2 Server Service Manual
- Sun Fire X2100 M2 Server Safety and Compliance Guide
|
|
Acoustic Noise Emissions
|
|
Acoustic Noise Emissions
|
Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling
|
|
|
LwAd (1B = 10dB)
|
Idle, at or below 25° C
6.9B Max, at ambient: 7.3B
|
|
Regulations
|
|
|
Meets or exceeds the following requirements:
|
|
|
Safety
|
IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences
|
|
|
RFI/EMI
|
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003
|
|
|
Immunity
|
EN55024, EN300-386:v1.3.2
|
|
Certifications
|
|
Safety
|
CE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S Mark
|
|
|
EMC
|
CE Mark, Emissions and Immunity Class A Emissions Levels: FCC, C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark
|
|
|
Other
|
Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive, Reduction of Hazardous Substances Compliant
|