Date: 26-Nov-2009   URL: www.sun.com/servers/entry/x2100/specs.xml

Sun Fire X2100 M2 Server

Specifications


Key Specifications

  • One AMD Opteron processor
  • Memory capacity up to 8 gigabytes
  • IPMI 2.0 service processor standard and embedded Lights Out Management
  • Up to 1.5 TB of onboard storage
  • Compact 1 RU form factor and multiple 32-bit and 64-bit operating systems
Performance data
Processor One dual core Next-Generation AMD Opteron model 1200 Series (models 1220 (2.8 GHz), 1218 (2.6 GHz), 1210 (1.8 GHz))

Memory Up to 8 GB; 4 DIMM slots, DDR2/667 Unbuffered ECC DIMMs (128 bit plus ECC databus), 512 MB, 1 GB, 2 GB DIMMs supported, installed in pairs

Networking Four Integrated 10/100/1000Base-T Ethernet ports

PCI Slots 2x 8-lane PCI-Express
Mass Storage
Internal disk
  • Up to two hot-pluggable 3.5" SATA II or SAS disk drives
  • 250 GB, 500 GB, 750 GB or 1 TB 7200 rpm 3.5" SATA II drives supported
  • 146 GB or 300 GB 15K rpm 3.5" SAS drives supported with optional HBA

Removable Media Up to one EIDE DVD-ROM or DVD+/-RW DL drive

RAID RAID 0/1/0+1 with optional 4-port SAS HBA; all supported operating systems with pair of SATA II or SAS drives

External Storage Supported Storage

Option Cards Sun has interoperability tested and supports a full suite of 4 GB and 2 GB Host Bus Adapters (HBAs). These HBAs offer unique features and benefits including Solaris integration and heterogeneous OS support. In the case of a Solaris environment, Sun HBAs combined with Sun Solaris OS provide the fastest, most reliable failover, highest availability, increased performance and dynamic load balancing by utilizing the Solaris SAN Foundation Suite drivers.
Software
Operating Systems Solaris OS, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, and Microsoft Windows. See supported Operating Systems.

Languages C/C++, FORTRAN (Solaris 10 OS), the Java programming language, all other standard Sun-supported languages

Networking ONC, ONC+, NFS, WebNFS, TCP/IP, SunLink software, OSI, MHS, IPX/SPX, SMB technologies, XML

Management Service processor with embedded Lights Out Management (LOM) standard.

Provides IPMI 2.0 in-band and out-of-band management.

Service processor is functionally equivalent to the ILOM used in the Sun Fire X4100 and X4200 servers.

See the Embedded Lights Out Manager Adminstration Guide
Management
Feature Standard Service Processor with embedded LOM

Remote Power/power cycle systems Yes

Monitor key system components (CPU, Voltages, Chassis temperature, fans) Yes

Comprehensive hardware monitoring Yes

DMTF SMASH CLI command set Yes

Serial & Network Access Yes

Dedicated Management Port Yes

Serial-Over-LAN support (SOL) Yes

SSH support Yes

Console Redirection Yes

Comprehensive Browser interface Yes

Remote KVM Yes

Remote Media capability (DVD, CD, Floppy) Yes

Simple GUI or CLI driven BIOS and firmware upgrade procedure Yes

IPMI support IMPI v2.0

SNMP support Yes
Environmental
Operating temperature (single, non-rack system) 5° C to 35° C (41°F to 95° F), 10% to 90% relative humidity, non-condensing, 27° C max wet bulb

Nonoperating temperature (single, non-rack system) -40 C to 65° C (-40° F to 149° F), up to 93% relative humidity, non-condensing, 38° C max wet bulb

Altitude (operating) (single, non-rack system Up to 3,000 m, maximum ambient temperature is derated by 1° C per 300 m above 500 m

Altitude (nonoperating) (single, non-rack system) Up to 12000 m
Power
Quantity of Power Supplies One

Power Supply UL Maximum (AC input) 6.5 Amps

Power Supply Rating (DC output) 345 Watts

In Use System Power See the X2100 Power Calculator
Dimensions and Weight
Height 43 mm (1.7")

Width 425.5mm (16.8")

Depth 633.7 mm (25")

Weight (Maximum) 10.7 kg (23.45 lbs)
Mounting Options
Mounting Options
  • 19-inch rackmount kit
  • Express 19-inch rackmount kit (tooless)
Documentation
Product Documentation Latest Documents
  • Where to Find Sun Fire X2100 M2 Server Documentation
  • Sun Fire X2100 M2 Server Product Notes
  • Sun Fire X2100 M2 Server Operating System Installation Guide
  • Embedded Lights Out Manager Adminstration Guide (X2100 M2)
  • Sun Fire X2100 M2 Server Installation Guide
  • Sun Fire X2100 M2 Server Service Manual
  • Sun Fire X2100 M2 Server Safety and Compliance Guide
Acoustic Noise Emissions
Acoustic Noise Emissions Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling

LwAd (1B = 10dB) Idle, at or below 25° C
6.9B Max, at ambient: 7.3B
Regulations
Meets or exceeds the following requirements:

Safety IEC 60950, UL/CSA60950, EN60950, CB scheme with all country differences

RFI/EMI FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.31, ICES-003

Immunity EN55024, EN300-386:v1.3.2
Certifications
Safety CE Mark, GOST, GS Mark, cULus Mark, CB scheme, CCC, S Mark

EMC CE Mark, Emissions and Immunity Class A Emissions Levels: FCC, C-Tick, MIC, CCC, GOST, BSMI, ESTI, DOC, S Mark

Other Labeled per WEEE (Waste Electrical and Electronic Equipment) Directive, Reduction of Hazardous Substances Compliant
 
 
Copyright 2004-2009 Sun Microsystems, Inc.