Number of processors
Up to 64 UltraSPARC(r) II 400 or 466 MHz processors
Architecture
UltraSPARC® processors
Cache per processor
End-to-end data integrity with ECC on memory and interconnect, and 8-MB mirrored external cache
CPU interface
64-bit Ultra Port Architecture (UPA).
Back to top
Up to 64 UltraSPARC(r) II 400 or 466 MHz Processors.
1 to 16 third-generation Dynamic System Domains.
Up to 64 GB Memory.
Support for up to 65 SBus or 32 PCI Cards.
Support for more than 100 TB of storage.
Back to top
Maximum of 16 boards per Enterprise 10000 server; minimum configuration is one system board, each holding up to four processors, up to four SBus cards or two PCI cards, and a memory module with four banks of eight SIMMS each.
Back to top
Up to 64GB memory capacity per system, each a group of 8 SIMMs.
Back to top
SBus
Support for up to 64 Sbus or 32 PCI cards
PCI
32-bit or 64-bit data bus width, 33 MHz or 66 MHz
Back to top
Mass Storage
Support for more than 100 TB of storage
Disk tray
Sun StorEdge[tm] D1000
Sun Netra[tm] st D130
Back to top
SunSwift Ethernet Fast/Wide UltraSCSI Host Adapter
SunFastEthernet[tm] Adapter
Sun[tm] Gigabit Ethernet Adapter
Sun[tm] Cluster 2.1 Board
SunHSI[tm] High Speed Serial Interface Adapter
Single-Ended Fast/Wide SCSI Host Adapter
Differential Fast/Wide SCSI Host Adapter
Dual-Loop FC-AL Host Adapter
Fast Write Cache
Back to top
Sun[tm] HIPPI/P High Performance Interface Board
Sun Enterprise[tm] Systems Interface Adapter (ESCON(r))
Sun ATM[tm] Adapter
Dual Fibre Channel Network Adapter
Single Fibre Channel Network Adapter
Back to top
Redundancy of key components, including
centerplace support boards, disk arrays, I/O, system power & cooling, AC line cords and breakers, control boards and
consoles
Back to top
Dynamic System Domains
Alternate Pathing
Dynamic Reconfiguration
On-line hot swap of boards, power, and cooling components
N+1, Fault-tolerant power and cooling
N+1, Redundant AC line cords and breakers
Redundant Control Boards
Monitoring tools
Automatic system recovery
Automated SSP failover
Automated Control Board failover
ECC on memory and Interconnect
Complete parity checking
Environmental monitoring
Remote system monitoring and support via SRS Net Connect
Redundant consoles
Interconnect data path and address path resiliency
Back to top
Operating System
Solaris[tm] 2.6, 7 or 8 Operating Environment
Languages
C, C++, Pascal, FORTRAN, Java[tm]
Networking
ONC[tm]
NFS[tm]
TCP/IP
SunNet[tm] OSI
MHS
X.25
DCE
Netware
System monitoring
Hostview and Sun Management Center
System and network management
Solaris Resource Manager[tm], Solaris Bandwidth Manager[tm], Solstice Suite Manager[tm], Solstice Domain Manager[tm], Solstice Backup[tm], Solstice DiskSuite[tm], Sun StorEdge[tm] Volume Manager
Back to top
AC power
200-240 single phase VAC, 47-63 Hz, 24 A per line cord (up to five redundant line cords)
Operating
10°C - 31°C (50°F - 88°F), at altitudes up to 10,000 ft
Back to top
Meets or exceeds the following requirements:
Safety
UL 1950, CUL CAN/CSA 22:2 M950, TUV EN60950
RFI/EMI
FCC Class A, EN50021-1 Class A
Immunity
EN50082-1
Back to top
Height
178 cm (70 in.)
Width
99 cm (39 in.)
Depth
127 cm (50 in.)
Weight
Main Cabinet: 818 kg (1800 lb.) approximately, fully-configured
Power cord
4.3 m (15 ft.)
Back to top
One year on-site hardware warranty with four hour response and ServerStart[tm] installation
One year software warranty
Warranty upgrades and service contracts available
Back to top
Professional Services
Application Readiness Service, Data Center Readiness Service, Sun Ready Availability Assessment, Sun Production Design Services
Support Services
SunSpectrum Platinum, Sun VIP Program, Sun Remote Services
Back to top
>