System
|
| |
32 CPU
|
64 CPU
|
|
Processor Specifications
|
- SPARC V9 Architecture, ECC protected
- Cache per processor (Level 1):
- SPARC64VII: 64-KB D-cache and 64-KB I-Cache
- SPARC64VI: 128-KB D-cache and 128-KB I-Cache
- Cache per processor (Level 2):
- SPARC64VII: 6-MB on-chip
- SPARC64 VI: 5-MB to 6-MB on-chip
- Clock speed:
- SPARC64 VII: 2.52GHz to 2.88GHz*
- SPARC64 VI: 2.28GHZ to 2.4GHz
|
|
|
CPU Memory Boards
|
Up to 8
|
Up to 16
|
|
|
Processors
|
Up to 4 and up to 256GB memory per board based on 8GB DIMMs
|
|
|
Main Memory
|
Up to 2TB per domain / system
|
Up to 4TB per domain / system
|
|
|
IO Units (IOU)
|
Up to 8 with 8 PCIe slots each / 64 PCIe slots per system
|
Up to 16 with 8 PCIe slots each / 128 PCIe slots per system
|
|
|
PCIe/PCI-X slots
|
Up to 224 with the optional External IO Expansion Unit
|
Up to 288 with the optional External IO Expansion Unit
|
|
|
System Bus Bandwidth
|
- (Memory) 368 GB/s peak, 114.920 GB/s stream (Copy)
- (IO) 122 GB/s PEAK
|
- (Memory) 737 GB/s peak, 224.401 GB/s stream (Copy)
- (IO) 244 GB/s PEAK
|
|
|
Interconnect System Bus
|
High-speed, low-latency with redundant data, address, and response crossbar interconnect
|
|
|
Service Processors
|
2 redundant per system
|
|
|
Dynamic Domains
|
Up to 24
|
|
Mass Storage
|
| |
32 CPU
|
64 CPU
|
|
Storage
|
Up to 32 internal, 2.5” SAS boot disks / 4 per IOU
|
Up to 64 internal, 2.5” SAS boot disks / 4 per IOU
|
|
|
External Boot Devices Supported
|
- StorageTek 2540
- StorageTek 3120
- StorageTek 3510FC
- StorageTek 9985
- StorageTek 9990
- Sun Storage J4200
- Sun Storage J4400
- Sun Storage J4500
|
|
Resource Management
|
|
Resource Management
|
Dynamic Domains, Solaris Resource Manager including Solaris Containers
|
|
Software
|
|
Operating System
|
SPARC64 VII (2.88GHz): Solaris 10 (10/08)
SPARC64 VII (2.52GHz): Solaris 10 (8/07) or later
SPARC64 VI (2.28GHz, 2.4GHz): Solaris 10 (11/06) or later
|
|
|
Languages
|
C, C++, Pascal, FORTRAN, Java
|
|
|
Networking
|
ONC/NFS, TCP/IP, SunLink Netware
|
|
|
System
|
Sun Management Center monitoring, Solaris Web Start, Solstice Domain Manager, Solstice Enterprise Manager, Solstice Backup, xVM Ops Center
|
|
|
Value Added Software
|
Sun Cluster, Sun HPC ClusterTools, Sun Java Enterprise System
|
|
Environmental
|
| |
32 CPU
|
64 CPU
|
|
Power Option 1
|
AC power 200–240 VAC 1-phase (50/60 Hz), 30 Amp, Five power cords (Ten with the optional dual power feed, length: 3m / 9.8 ft)
Plug NEMA-L6-30P or EN60309 (32A)
|
AC power 200–240 VAC 1-phase (50/60 Hz), 30 Amp, Ten power cords (Twenty with the optional dual power feed, length: 3m / 9.8 ft)
Plug NEMA-L6-30P or EN60309 (32A)
|
|
|
Power Option 2
|
AC power 208VAC 3-phase DELTA (50/60 Hz), 80 Amp, Two direct wired power connections, includes DPF
|
AC power 208VAC 3-phase DELTA (50/60 Hz), 80 Amp, Four direct wired power connections, includes DPF
|
|
|
Power Option 3
|
AC power 415 VAC 3-phase STAR (50/60 Hz), 50 Amp, Two direct wired power connections, includes DPF
|
AC power 415 VAC 3-phase STAR (50/60 Hz), 50 Amp, Four direct wired power connections, includes DPF
|
|
|
Operating Temperature/Humidity
|
5°C to 32°C (41°F to 89.6°F), 20% to 80% relative humidity, noncondensing
|
|
|
Nonoperating Temperature/Humidity
|
0°C to 50°C (32°F to 122°F) 8% to 80% relative humidity, noncondensing
|
|
|
Altitude
|
Up to 3000 m (9,843 ft.)
|
|
RAS
|
| |
32 CPU
|
64 CPU
|
|
Key RAS Features
|
- End-to-end ECC protection
- Guaranteed data path integrity
- Automatic recovery
- Auto-reconfiguration after reboot
- Blacklist of failed field replacement units (FRUs)
- Blacklist of failed ASIC's
- Reconfiguration and recovery of centerplane with an ASIC failure
- Instruction retry
- Processor SRAM and register protection
- ECC and extended protection for memory
- Memory mirroring
- Predictive self-healing
- Hardware Redundancy on major components
- Fault-isolated Dynamic Domains
- Dynamic Reconfiguration
- Auto Diagnosis and Recovery
- Proactive self-diagnostics
- Online upgrades (add new resources while system is operational)
- Concurrent maintenance (service while system is operational)
- Redundant network connections
- Redundant service processors
- Redundant storage connections
- Live operating system upgrades
- Journaled file system
- Hardened I/O drivers
- CPU off-lining
- Memory page retirement
- Cluster support
|
|
Dimensions and Weight
|
| |
32 CPU
|
64 CPU
|
|
Height
|
180 cm (70.9 in.)
|
180 cm (70.9 in.)
|
|
|
Width
|
85 cm (33.5 in.)
|
167.4 cm (65.9 in.)
|
|
|
Depth
|
126 cm (49.6 in.)
|
126 cm (49.6 in.)
|
|
|
Weight
|
940 kg (2,072 lb.)
|
1880 kg (4,145 lb.)
|
|
Optional Power Expansion Cabinet
|
| |
32 CPU
|
64 CPU
|
|
|
(required for 1phase DPF or 3-phase power distribution, one required for 32 CPU system, 2 required for 64 CPU system)
|
|
|
Height
|
180 cm (70.9 in.)
|
180 cm (70.9 in.)
|
|
|
Width
|
31.7 cm (12.5 in.)
|
31.7 cm (12.5 in.)
|
|
|
Depth
|
124.4 cm (49 in.)
|
124.4 cm (49 in.)
|
|
|
Weight
|
350 kg (770 lb.)
|
350 kg (770 lb.)
|
|
Remote Services
|
|
Remote Services
|
Sun Connect
|