System
|
|
Expansion Capacity
|
- Chassis will accept and operate up to 2 I/O boats for a maximum of 12 expansion slots
- I/O boats providing 6 expansion slots are offered in either 6PCIe (x8 lane) or PCI-X versions
- Each I/O boat includes 6 card carriers (plus 1 Link carrier) already installed
- Card carriers allow for all PCIe or PCI-X card form factors to be installed in the I/O boat
- Both I/O boats are intended to expand the PCIe or PCI-X capacity of a single server.
|
|
|
Link to Host
|
- Host server management & control is established via PCIe link cards mounted in both host server and special reserved slot (slot 0) in each IO boat
- Link cards are either copper (M4000, M5000, and T-Series only, 4m cable length) or fiber optic (M4000, M5000 or M8000, M9000, 10 or 25m optical fiber length)
- Link cards are hot pluggable and utilize sideband communication in conjunction with expansion port I/O traffic
- Link card connections are easily established with server in minutes, then expansion slots are available as though they were internal to the host server.
|
|
Maximum Servers Supported
|
|
Sun SPARC Enterprise M3000 Server
|
Not supported
|
|
|
Sun SPARC Enterprise M4000 Server
|
- 4 processors
- 2x External I/O Expansion Units (4x I/O Boats)
- 24 Additional External Slots
|
|
|
Sun SPARC Enterprise M5000 Server
|
- 8 processors
- 4x External I/O Expansion Units (8xu I/O Boats)
- 48 Additional External Slots
|
|
|
Sun SPARC Enterprise M8000 Server
|
- 16 processors
- 8x External I/O Expansion Units (16x I/O Boats)
- 96 Additional External Slots
|
|
|
Sun SPARC Enterprise M9000 Server, 32 CPU
|
- 32 processors
- 16x External I/O Expansion Units (32x I/O Boats)
- 192 Additional External Slots
|
|
|
Sun SPARC Enterprise M9000 Server, 64 CPU
|
- 64 processors
- 16x External I/O Expansion Units (32x I/O Boats)
- 192 Additional External Slots
|
|
|
Sun SPARC Enterprise T1000 Server
|
Not supported
|
|
|
Sun SPARC Enterprise T2000 Server
|
Not supported
|
|
|
Sun SPARC Enterprise T5120 Server
|
- 1 processor
- 1x External I/O Expansion Unit (1x I/O Boat, PCIe only)
- 6 Additional External Slots
|
|
|
Sun SPARC Enterprise T5140 Server
|
- 2 processors
- 1x External I/O Expansion Unit (2x I/O Boats, PCIe only)
- 12 Additional External Slots
|
|
|
Sun SPARC Enterprise T5220 Server
|
- 1 processor
- 1x External I/O Expansion Unit (2x I/O Boats, PCIe only)
- 12 Additional External Slots
|
|
|
Sun SPARC Enterprise T5240 Server
|
- 2 processors
- 1x External I/O Expansion Unit (2x I/O Boats, PCIe only)
- 12 Additional External Slots
|
|
|
Sun SPARC Enterprise T5440 Server
|
- 4 processors
- 2x External I/O Expansion Units (Max 2)
(4x I/O Boats, one Boat per processor, PCIe only)
- 24 Additional External Slots
|
|
Storage
|
|
Storage Specifications
|
No internal boot/storage devices are supported within External
IO Expansion Unit
|
|
Environmental
|
|
Voltage
|
- A100 to 240 (50/60 Hz (+/-3%) and
voltage within ±10%) (AC)
- Receptacle type: IEC 60320 C20
|
|
|
Power Consumption
|
600 (W)
|
|
|
Power Factor
|
0.95 (A0-p)
|
|
|
Rush Current
|
30 (A)
|
|
|
Leak Current
|
1.5 (mA)
|
|
|
Fuse Capacity
|
15(A)(for each power supply)
|
|
|
Redundant Power Supply/Fan Unit
|
2x - 120 mm Fan/PSU combined unit, Redundant and Hot-Pluggable
|
|
|
Temperature
|
- Operating: 2 to 35°C (36 to 95°F)
- Nonoperating: 0 to 68°C (32 to 154°F)
|
|
|
Altitude
|
- Operating: 0 to less than 3200 m (10498.69 ft.) above sea level
- Nonoperating: 0 to less than 13000 m (42650.92 ft.) above sea level
|
|
|
Humidity
|
- Operating: 7% to 93% RH, 35C, 16 hour dwell
- Nonoperating: 93% RH, 40C, 5 days dwell
|
|
|
Heat Dissipation
|
2100 (kJ/h)
|
|
|
Exhaust Airflow
|
2.55 (m3/min.)
|
|
|
Noise Level
|
<85 dBA
|
|
|
Cooling Method
|
Forced Air, Front to Back
|
|
|
Vibration Feature Specifications Operating
|
0.15g (vertical); 0.10g (horizontal),
5 to 500 Hz, swept-sine
|
|
|
Seismic wave [gal]
|
3.0mm pk-pk 0.5g (vertical); 0.25
(horizontal), 5 to 500 Hz, swept-sine
|
|
Regulations
|
|
Safety
|
CSA/UL-60950, EN60950, IEC950 CB Scheme with all national deviations
|
|
|
RFI/EMC
|
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A, EN61000-3-2, EN61000-3-3
|
|
|
Immunity
|
EN55024,
EN61000-4-2, -4-3. -4-5. -4-6, -4-8
and -4/11
|
|
|
Regulatory markings
|
CE, FCC, ICES, C-tick, VCCI, GOST-R, BSMI, MIC, CSA/UL
|
|
|
Other Marks
|
WEEE and Chinese RoHS
|
|
Dimensions and Weight (4RU Chassis)
|
|
External dimensions
|
444.5 x 711.2 x 170.3mm
|
|
|
Weight
|
73.40lbs, 33.36Kgs
|