Processor
|
|
Processor Specifications
|
- Ability to mix and match up to 8 SPARC64 VII quad-core processors or
SPARC64 VI dual-core processors in the same system
- SPARC V9 Architecture, ECC protected
- Cache per processor (Level 1):
- SPARC64 VII: 64-KB D-cache and 64-KB I-Cache
- SPARC64 VI: 128-KB D-cache and 128-KB I-Cache
- Cache per processor (Level 2):
- SPARC64 VI 2.15GHz: 5 MB on-chip
- SPARC64 VII 2.53GHz: 5.5 MB on-chip
- Clock speed:
- SPARC64 VII: 2.53GHz
- SPARC64 VI: 2.15GHz
|
|
System
|
|
System Specifications
|
- Up to 4 CPU boards; 2 CPUs per board
- Up to 256 GB, using 4 GB DIMMs (32 GB per memory board x 8 boards)
- Up to 10 I/O slots with 8 PCIe slots each and 2 PCI-X (4 PCIe and 1 PCI-X per I/O tray)
- Up to 50 PCIe or PCI-X slots with optional External I/O Expansion Unit
- High-speed, low-latency interconnect system bus with redundant data, address, and response crossbar interconnect
- System Bus bandwidth (Memory) 64 GB/s peak, 24.831 GB/s stream (Copy)
- System Bus bandwidth (IO) 16GB/s PEAK
- Up to 4 1Gb Ethernet ports (2 1Gb Ethernet ports per I/O tray)
- Service Processor for system management
- Up to 4 dynamic domains
|
|
Storage
|
|
Storage Specifications
|
- Boot device: Up to 4 internal, 2.5" SAS boot disks
- External direct, SAN or NAS attach to Sun StorageTek compatible tape libraries and disk arrays, including Sun StorageTek 3X00, 5X00, 6X00, 9X00, and Jx000 families
|
|
Resource Management
|
|
Resource Management
|
Dynamic Domains, Solaris Resource Manager including Solaris Containers
|
|
Software
|
|
Operating System
|
SPARC64 VII (2.53GHz): Solaris 10 (8/07)* and later
SPARC64 VI: Solaris 10 (11/06) or later
|
|
|
Languages
|
C, C++, Pascal, FORTRAN, Java
|
|
|
Networking
|
ONC/NFS, TCP/IP, SunLink Netware
|
|
|
System
|
Sun Management Center monitoring, Solaris Web Start, Solstice Domain Manager, Solstice Enterprise Manager, Solstice Backup, xVM Ops Center
|
|
|
Value Added Software
|
Sun Cluster, Sun HPC ClusterTools, Sun Java Enterprise System
|
|
Environmental
|
|
Power
|
- AC power 100–240 VAC 1-phase (50/60 Hz), 12 amp per power cord, 2-4 power cords
- Plug NEMA-L6-20P (U.S.) or IEC 309-IP44 (INTL) IEC 60320 C19 connector.
- Receptacle type: IEC 60320 C20
|
|
|
Operating temperature
|
5°C to 35°C (41°F to 95°F), 20% to 80% relative humidity, noncondensing
|
|
|
Nonoperating temperature
|
-20°C to 60°C (-4°F to 140°F) 8% to 93% relative humidity, noncondensing
|
|
|
Altitude
|
Up to 3000 m (9,843 ft)
|
|
Regulations
|
|
Safety
|
CSA/UL-60950, EN60950, IEC950 CB Scheme with all national deviations
|
|
|
RFI/EMC
|
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A, EN61000-3-2, EN61000-3-3
|
|
|
Immunity
|
EN55024, EN61000-4-2, -4-3. -4-5. -4-6, -4-8 & -4/11
|
|
|
Regulatory Markings
|
CE, FCC, ICES, C-tick, VCCI, GOST-R, BSMI, MIC, CSA/UL
|
|
|
Other Marks
|
WEEE and Chinese RoHS
|
|
RAS
|
|
Key RAS Features
|
- End-to-end ECC protection
- Guaranteed data path integrity
- Automatic recovery
- Auto-reconfiguration after reboot
- Dynamic L1 and L2 cache line degradation
- Blacklist of failed field replacement units (FRUs)
- Blacklist of failed ASIC's
- Reconfiguration and recovery of centerplane with an ASIC failure
- Instruction retry
- Processor SRAM and register protection
- ECC and and extended protection for memory
- Memory mirroring
- Predictive self-healing
- Fault-isolated Dynamic Domains
- Dynamic Reconfiguration
- Auto Diagnosis and Recovery
- Proactive self-diagnostics
- Hot-swap of power, cooling, and I/O
- Concurrent maintenance of disks, fans, and power supplies (service while system is operational)
- Redundant network connections
- Redundant storage connections
- Live operating system upgrades
- Journaled file system
- Hardened I/O drivers
- Individual core or CPU off-lining
- Memory page retirement
- Cluster support
|
|
Dimensions and Weight
|
|
Height
|
44.02 cm (17.33 in.)
|
|
|
Width
|
44 cm (17.33 in.)
|
|
|
Depth
|
81 cm (31.9 in.)
|
|
|
Weight
|
275 lb (125 kg)
|
|
Remote Services
|
|
Remote Services
|
Sun Connect
|