Processor
|
|
Processor
|
Combine up to twelve 1.95 GHz UltraSPARC IV+ processors and/or 1.8 GHz UltraSPARC IV+ and/or 1.5 GHz UltraSPARC IV+ processors and/or 1.35 GHz UltraSPARC IV processors
|
|
|
Architecture
|
Superscalar SPARC V9, ECC protected
|
|
|
Cache per UltraSPARC IV+ processor
|
- Level 1: 64 KB data and 64 KB instruction per pipeline
- Level 2: 2 MB on-chip
- Level 3: 32 MB external
|
|
System
|
|
Processor/memory boards
|
Up to three CPU/memory boards*, with four processors each, and up to 64 GB per board; maximum 12 processors per server *The Sun Fire E2900 server CPU/memory board is common, and therefore interchangeable, with the Sun Fire V1280 server. However, these boards are not identical to and thus not inter-changeable with the Sun Fire E4900–E25K server Uniboard technology.
|
|
|
Main Memory
|
Up to 192 GB per system
|
|
|
PCI-X
|
- Six short PCI-X slots (64-bit 100 MHz,3.3V)
- One integrated Ultra-320 SCSI (one internal and one external port)
- Two Gigabit Ethernet ports with another two on a separate grid
|
|
|
System interconnect
|
9.6-GB/sec. Sun Fireplane interconnect. System bus with redundant data, address and response crossbar interconnect
|
|
|
System bandwidth
|
9.6-GB/sec. sustained bandwidth, 31.2-GB/sec. aggregate bandwidth
|
|
Storage
|
|
Internal
|
- Two 146-GB 15K rpm Ultra3-SCSI internal disks
- DVD-ROM internal drive
- Tape drive (optional)
|
|
|
External compatibility
|
Direct attach to Sun StorageTek tape libraries and disk arrays, including: Sun StorageTek 3000, 6000, and 9000 families, providing excellent linear scalability
x
|
|
Resource Management
|
|
Standard
|
Solaris Resource Manager, Solaris Bandwidth Manager
|
|
Software
|
|
Operating System (minimum version)
|
- The minimum OS version for 1.95 GHz, 1.5 GHz and 1.8 GHz UltraSPARC IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1
- The minimum OS version for UltraSPARC IV processors is Solaris 8
2/04, Solaris 9 4/04, or Solaris 10 3/05
|
|
|
Enterprise software
|
Sun Java Enterprise System
|
|
|
Languages
|
- C
- C++
- Pascal
- FORTRAN
- Java
|
|
|
Networking
|
- ONC/NFS
- TCP/IP
- SunLink
- OSI
- X.25
- DCE
- Netware
|
|
|
System Management and Enterprise Computing
|
- Sun Management Center
- Sun Cluster
- Sun HPC ClusterTools
|
|
Environmental
|
|
AC power
|
200-240V single phase AC, 47-63 Hz, with two 11/13 Amp circuits redundant with another two on a separate grid
|
|
|
Optimum
|
22° C (72° F) at 45% non condensing humidity
|
|
|
Range
|
5° C to 35° C (41° F to 95° F) at 10% to 80% non condensing humidity
|
|
|
Altitude
|
- Up to 3,048 m (10,000 ft.)
- Up to 2,134 m (7,000 ft.) for 1.8GHz and 1.95 GHz UltraSPARC IV+
|
|
Dimensions and Weight
|
|
Height
|
52.7 cm (20.75 in.)12RU
|
|
|
Width
|
44.5 cm (17.5 in.)
|
|
|
Depth
|
55.8 cm (22.0 in.) excluding cable arm
|
|
|
Weight
|
110-132 kg (240-290 lb.)
|
|
|
Rackmount enclosure
|
All Sun racks and most third-party 24-in. (600 mm) and deeper racks, two per 4-post rack, one per 2-post rack
|
|
Regulations
|
|
Regulations
|
Meets or exceeds the following requirements:
|
|
|
Safety
|
UL 60950, third-edition USA CAN/CSA-C22.2 No. 60950-00, Canada EN 60950, third-edition, Europe S Mark, Argentina Gost-R, Russia CB Scheme with all national deviations
|
|
|
Emissions
|
EN55022 Class A, Europe EN6100-3-2 / 3-3, Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS-13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia
|
|
|
Immunity
|
All European requirements EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000- 4-6, EN61000-4-8, EN61000-4-11, and EN300-386
|
|
|
Regulatory markings
|
CE, FCC, ICES-003, C-tick, VCCI, Gost-R, BSMI, UL/cUL/S Mark, TUV-GS, MIC, RoHS
|
|
Key RAS Features
|
|
Key RAS Features
|
Dynamic Reconfiguration (DR) of processor/memory boards, hot CPU upgrades, redundant Sun Fireplane interconnect, redundant network connections, hot-swap disks, smart fans, 2N redundant hot-swap power supplies, Auto Diagnosis & Recovery, hardened operating system kernel, hardened I/O drivers, Systems Configuration Card, proactive self diagnostics, end-to-end data integrity including ECC, CPU off-lining, memory page retirement, after-kernel hot patching, and cluster support.
|
|
Trade in and Save
|
|
Trade in and Save
|
The Sun Upgrade Advantage Program (UAP) offers trade-in value for qualified Sun and competitive servers toward the purchase of replacement Sun Fire E2900 server(s). Whether upgrading one system or consolidating many systems to one, Sun UAP offers the flexibility to trade in and receive credit toward the new Sun system purchased. Upgrades are also available for Sun Fire server system components, including CPU/memory boards and I/O. For more information visit http://www.sun.com/tradeins/offerings/mid.jsp.
|
|
Remote Services
|
|
Remote Services
|
SRS Net Connect
|
|
Services
|
|
Services
|
Sun provides a worldwide services portfolio that helps enable customers to develop a Sun Fire E2900 solution designed for reliability, availability, serviceability, and growth. Sun can assist you to build an architecture plan, assess your current IT infrastructure, improve staff skills and efficiencies, and properly install your Sun Fire E2900 system in your environment. Services highlights include: Sun Preventive Services, Enterprise Installation Services, Learning Services, Architecture Services, Migration/Consolidation Services, Sun Managed Services, and the Accredited Installation Provider program. For more information on Sun Services, please visit http://www.sun.com/service.
|