Specifications

 
   Specifications
 

No Longer Orderable
The Sun Fire V480 Server has been retired and is no longer orderable.

Processor
Processor
1.05/1.2 GHz UltraSPARC III Cu
Architecture
Superscalar SPARC V9
Processor modules
One or two dual-processor memory modules
Cache (on chip)
64 KB data and 32 KB instruction
Secondary cache (L2)
8 MB external
System Interconnect
Sun Fireplane interconnect, 9.6 GBps

Back to Top

 
Capacity
Up to 32 GB main memory
Up to 2 hot-swap disk drives
Up to 6 PCI slots

Back to Top

 
Main Memory
A system maximum of 32 GB when configured with four processors

Back to Top

 
Standard/Integrated Interfaces
Network
Two 10/100/1000-Mbps Ethernet ports
I/O
FC-AL disk controller, two USB ports
Serial
RJ45 serial port
Expansion
Six 64-bit PCI slots compliant with PCI specification Revision 2.1:
  • Two at 66 MHz, 3.3 volts
  • Four at 33 MHz, 5 volts

Back to Top

 
Mass Storage and Media
Host adapters
Internal IDE to support the internal DVD-ROM drive
Internal disk
Two 3.5-inch x 1.0-inch 10,000 RPM FC-AL disks, 73 GB drive
Internal DVD
DVD-ROM drive
External disk
  • Sun StorEdge MultiPack systems
  • Sun StorEdge A1000
  • Sun StorEdge D1000
  • Sun StorEdge A5200
  • Sun StorEdge T3
  • Sun StorEdge D2
  • Sun StorEdge S1
  • Sun StorEdge 3900/6900
  • Sun StorEdge 9900
External tape
SCSI tape devices via a SCSI host bus adapter:
  • Sun StorEdge 12 GB DDS-3 UniPack
  • Sun StorEdge DDS-3 Autoloader FlexiPack
  • Sun StorEdge 20 GB DDS-4 UniPack
  • Sun StorEdge DL T8000 FlexiPack
  • Sun StorEdge L9 tape autoloader
  • Sun StorEdge L20 tape library family
  • Sun StorEdge L180 tape library
  • Sun StorEdge L700 tape library
  • Sun StorEdge L5500 tape library
  • Sun StorEdge L6000 tape library
(Utilization of the Sun StorEdge L180 and L700 tape libraries may be limited by the number of SCSI host bus adapters and buses available for connection to the server).

Back to Top

 
Software
Operating System
Solaris 8, Solaris 9 and Solaris 10
Languages
C, C++, Pascal, Fortran, Java
Networking
ONC, NFS, TCP/IP, SunLink OSI, MHS, IPX SPX
System monitoring
Sun Management Center
System and network management
  • Solaris Bandwidth Manager
  • Solaris Resource Manager
  • Sun Management Center
  • Sun Remote System Control
  • Sun Cluster
  • Solaris PC NetLink
  • Solaris WebStart
  • Solaris Web Start Wizards
  • Solstice Backup

Back to Top

 
Console Options
Monitor
Optional: Sun monitors from 1995 and later (17-, FP18-, 21-, and 24-inch monitors)
Frame buffer
Sun PGX64 8/24-bit
Keyboard and mouse port
USB keyboard and mouse
PCI options
Gigabit Ethernet, 10/100-MBps Ethernet, dual-channel FC-AL disks, single-channel FC-AL, Quad FastEthernet, token ring, FDDI, ATM-155, ATM-622, high-speed serial, Ultra SCSI with 10/100-MBps Ethernet, dual-channel single-ended Ultra SCSI, dual-channel differential Ultra SCSI

Back to Top

 
Power Supplies
One required, two for redundancy, each with independent power cord
Maximum AC input
1440 W per power supply
Maximum DC input
1184 W per power supply

Back to Top

 
Environment
AC power
100-240 VAC, 47-63 Hz, 0.895 KVA
Operating
5° C to 35º C (41º F to 95º F), 20% to 80% relative temperature humidity, noncondensing, 27º C maximum wet bulb
Nonoperating
-20º C to 60º C (-4º F to 140º F), 5% to 95% relative temperature humidity, noncondensing

Back to Top

 
Regulations
Meets or exceeds the following requirements:
Safety
UL 1950, CB Scheme IEC 950 (CE Mark), CSA C22.2 950 (from UL), TUV EN 60950
RFI/EMI
Class A:
  • Australia/New Zealand AS/NZ 3548
  • Industry Canada ICES-003
  • European Community EN55022/CISPR22
  • Japan VCCI
  • Taiwan CNS 13438
  • US FCC 47CFR15.B
Immunity
EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, IEC 61000-3-2, IEC 61000-3-3
X-Ray
U.S. DHHS 21CFR Subchapter J, PTB German X-ray decree

Back to Top

 
Dimensions and Weight
Height
5 RU, 222 mm (8.75 in.)
Width
446 mm (17.5 in.)
Depth
610 mm (24.0 in.)
Weight
Minimum: 35.8 kg (79 lb.)
Fully configured: 44 kg (97 lb.)
Power cord
4.0 m (13.13 ft.)
Rack-mount enclosure
Fits into a standard 19-in. wide rackmount kit that complies with EIA-310-D-1992 standard or a 72-in. high Sun StorEdge rack, which supports six Sun Fire V480 servers.

Back to Top

 
Upgrades
Upgrades are available for SPARC server and Sun Enterprise systems. Contact your local Sun sales representative for details.

Back to Top

 
Warranty
Hardware Support
3 years
Software Install
90 days
Call Response
8 hours
Deliver
Second business day, onsite

Back to Top

 
 
Give your business a boost