Processor
|
|
Processors
|
- Combine up to eight 2.1 GHz UltraSPARC IV+ processors.
- Combine up to eight 1.8 GHz and/or 1.5GHz UltraSPARC IV+ processors and/or 1.35 GHz UltraSPARC IV processors.
|
|
|
Architecture
|
Superscalar SPARC V9, ECC protected
|
|
|
Processor modules
|
One to four dual-processor/memory modules
|
|
|
Cache per UltraSPARC IV+ processor
|
- Level 1: 64-KB data and 64-KB instruction per pipeline
- Level 2: 2 MB on-chip
- Level 3: 32 MB external
|
|
Main Memory
|
|
Main Memory
|
A system maximum of 128 GB when configured with eight processors
|
|
Standard/Integrated Interfaces
|
|
Network
|
1-Gb Ethernet and 10/100Base-T Ethernet
|
|
|
I/O
|
FC-AL disk controller
|
|
|
Serial
|
Two EIA-232D or EIA-423 serial ports (DB25) via splitter cable
|
|
|
Expansion capability
|
Nine full-sized, hot-plug PCI slots compliant with PCI specification Revision 2.1 (2 @ 66 MHz, 64 bits wide, 3.3 volts; 7 @ 33 MHz, 64 bits wide, 5 volts)
|
|
|
USB
|
Two (compliant with USB Revision 1.0)
|
|
Mass Storage and Media
|
|
Internal tape
|
Optional 12-GB DDS-3 or 20-GB DDS-4 SCSI drive(s) via X6758A adapter and X912A cable options
|
|
|
Internal disk
|
Up to 12 3.5" x 1.0" 15K-RPM FC-AL disks (146-GB capacity) providing a maximum total capacity of 1.75 TB
|
|
|
External disk
|
- Sun StorageTek D240
- Sun StorageTek S1
- Sun StorageTek 3120
- Sun StorageTek 3310 SCSI RAID/JBOD
- Sun StorageTek 3320
- Sun StorageTek 3510 FC RAID/JBOD
- Sun StorageTek 3511
- Sun StorageTek 6140 Array
- Sun StorageTek 6920
- Sun StorageTek 9910/9960/9970/9980
|
|
|
External tape
|
- Sun StorageTek DAT 72 desktop tape drive
- Sun StorageTek LT0-2 desktop tape drive
- Sun StorageTek LT0 2V desktop tape drive
- Sun StorageTek LT0-3 desktop tape drive
- Sun StorageTek SDLT 320 desktop tape drive
- Sun StorageTek SDLT 600 desktop tape drive
- Sun StorageTek C2
- Sun StorageTek C4
- Sun StorageTek SL500
- Sun StorageTek SL700/SL1400 tape library
- Sun StorageTek SL8500 tape library
|
|
Software
|
|
Operating system (minimum version)
|
- The minimum OS version for 2.1GHZ, 1.8GHz and 1.5GHz UltraSPARC IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1
- The minimum OS version for 1.35GHz UltraSPARC IV processors is Solaris 8 2/04, Solaris 9 4/04, or Solaris 10 3/05
|
|
|
Enterprise infrastructure software
|
- Sun Java Enterprise System
- Sun Management Center
- Sun N1 System Manager
|
|
Power Supplies
|
|
Note
|
Two required, three for redundancy, each with independent power cord.
|
|
|
Maximum AC input
|
3200 W per system
|
|
|
Maximum DC output
|
2509 W per system
|
|
Environmental
|
|
AC power
|
200-240 VAC, 47-63 Hz, 2078 VA
|
|
|
Operating temperature
|
- 5° C to 35° C (41° F to 95° F), 20% to 80% relative humidity, non condensing, 27° C max. wet bulb
- 2.1 GHz UltraSPARC IV+ processor: ASHRAE Class 3 (35C/900m) and/or 28C/10kft
|
|
|
Non operating temperature
|
-20° C to 60° C (-4° F to 140° F), 95% at 40° C relative humidity, non condensing
|
|
Dimensions and Weight
|
|
Height
|
714 mm (28.1 in.) with casters
700 mm (27.6 in.) without casters (rackmounting does not require the removal of casters)
|
|
|
Width
|
480 mm (18.9 in.)
|
|
|
Depth
|
836 mm (32.9 in.)
|
|
|
Weight
|
88.1 kg (194.0 lb.) (min.)
130.9 kg (288.0 lb.) (fully configured)
|
|
Key RAS Features
|
|
Key RAS Features
|
- Hot-pluggable disk drives and PCI cards
- N+1 power supply redundancy
- Hot-swappable power supplies
- Redundant, hot-swappable fan trays
- Environmental monitoring and fault protection
- Automatic System Recovery (ASR)
- Remote Lights Out Management capability
- Support for disk and network multipathing with automatic failover capability
- Dual-loop enabled FC-AL mass storage system
- Error correction and parity checking for improved data integrity
|
|
Regulations
|
|
Note
|
Meets or exceeds the following requirements:
|
|
|
Safety
|
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336
|
|
|
Ergonomics
|
EK1-ITB-2000
|
|
|
RFI/EMC
|
EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3
|
|
|
Immunity
|
EN55024/CISPR24
|
|
|
Telecommunications
|
EN300-386
|
|
|
X-ray (for monitors)
|
DHHS 21 Subchapter J; PTB German X-ray Decree
|
|
|
Regulatory markings
|
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark
|
|
|
Other
|
Restriction of Hazardous Substances (RoHS) directive 2002/95/EC
Labeled per Waste Electrical and Electronic Equipment (WEEE) Directive
|
|
Trade in and Save
|
|
Upgrades
|
The Sun Upgrade Advantage Program (UAP) offers trade-in value for qualified Sun and competitive servers toward the purchase of replacement Sun Fire V890 server(s). Whether upgrading one system or consolidating many systems to one, Sun UAP offers the flexibility to trade in and receive credit toward the new Sun system purchased. Upgrades are also available for Sun Fire server system components, including CPU/memory boards and I/O. For more information visit http://www.sun.com/tradeins/offerings/mid.jsp.
|
|
Warranty
|
|
Hardware support
|
3 years
|
|
|
Software install
|
90 days
|
|
|
Call response
|
8 hours
|
|
|
Delivery
|
Next business day, on-site
|