Sun Fire V890 Server

EOL

Specifications


Key Specifications

  • Combine up to eight 2.1 GHz UltraSPARC IV+ processors or combine up to eight 1.8 GHz and/or 1.5GHz UltraSPARC IV+ processors and/or 1.35 GHz UltraSPARC IV processors.
  • Level 1 cache: 64-KB data and 64-KB instruction per pipeline
  • A system maximum of 128 gigabytes when configured with eight processors
  • The minimum OS version for UltraSPARC IV+ processors is Solaris 9 9/08 and Solaris 10 3/5 HW1
  • 17 RU Tower
Processor
Processors
  • Combine up to eight 2.1 GHz UltraSPARC IV+ processors.
  • Combine up to eight 1.8 GHz and/or 1.5GHz UltraSPARC IV+ processors and/or 1.35 GHz UltraSPARC IV processors.

Architecture Superscalar SPARC V9, ECC protected

Processor modules One to four dual-processor/memory modules

Cache per UltraSPARC IV+ processor
  • Level 1: 64-KB data and 64-KB instruction per pipeline
  • Level 2: 2 MB on-chip
  • Level 3: 32 MB external
Main Memory
Main Memory A system maximum of 128 GB when configured with eight processors
Standard/Integrated Interfaces
Network 1-Gb Ethernet and 10/100Base-T Ethernet

I/O FC-AL disk controller

Serial Two EIA-232D or EIA-423 serial ports (DB25) via splitter cable

Expansion capability Nine full-sized, hot-plug PCI slots compliant with PCI specification Revision 2.1 (2 @ 66 MHz, 64 bits wide, 3.3 volts; 7 @ 33 MHz, 64 bits wide, 5 volts)

USB Two (compliant with USB Revision 1.0)
Mass Storage and Media
Internal tape Optional 12-GB DDS-3 or 20-GB DDS-4 SCSI drive(s) via X6758A adapter and X912A cable options

Internal disk Up to 12 3.5" x 1.0" 15K-RPM FC-AL disks (146-GB capacity) providing a maximum total capacity of 1.75 TB

External disk
  • Sun StorageTek D240
  • Sun StorageTek S1
  • Sun StorageTek 3120
  • Sun StorageTek 3310 SCSI RAID/JBOD
  • Sun StorageTek 3320
  • Sun StorageTek 3510 FC RAID/JBOD
  • Sun StorageTek 3511
  • Sun StorageTek 6140 Array
  • Sun StorageTek 6920
  • Sun StorageTek 9910/9960/9970/9980

External tape
  • Sun StorageTek DAT 72 desktop tape drive
  • Sun StorageTek LT0-2 desktop tape drive
  • Sun StorageTek LT0 2V desktop tape drive
  • Sun StorageTek LT0-3 desktop tape drive
  • Sun StorageTek SDLT 320 desktop tape drive
  • Sun StorageTek SDLT 600 desktop tape drive
  • Sun StorageTek C2
  • Sun StorageTek C4
  • Sun StorageTek SL500
  • Sun StorageTek SL700/SL1400 tape library
  • Sun StorageTek SL8500 tape library
Software
Operating system (minimum version)
  • The minimum OS version for 2.1GHZ, 1.8GHz and 1.5GHz UltraSPARC IV+ processors is Solaris 9 9/05 or Solaris 10 3/05 HW1
  • The minimum OS version for 1.35GHz UltraSPARC IV processors is Solaris 8 2/04, Solaris 9 4/04, or Solaris 10 3/05

Enterprise infrastructure software
  • Sun Java Enterprise System
  • Sun Management Center
  • Sun N1 System Manager
Power Supplies
Note Two required, three for redundancy, each with independent power cord.

Maximum AC input 3200 W per system

Maximum DC output 2509 W per system
Environmental
AC power 200-240 VAC, 47-63 Hz, 2078 VA

Operating temperature
  • 5° C to 35° C (41° F to 95° F), 20% to 80% relative humidity, non condensing, 27° C max. wet bulb
  • 2.1 GHz UltraSPARC IV+ processor: ASHRAE Class 3 (35C/900m) and/or 28C/10kft

Non operating temperature -20° C to 60° C (-4° F to 140° F), 95% at 40° C relative humidity, non condensing
Dimensions and Weight
Height 714 mm (28.1 in.) with casters 700 mm (27.6 in.) without casters (rackmounting does not require the removal of casters)

Width 480 mm (18.9 in.)

Depth 836 mm (32.9 in.)

Weight 88.1 kg (194.0 lb.) (min.)
130.9 kg (288.0 lb.) (fully configured)
Key RAS Features
Key RAS Features
  • Hot-pluggable disk drives and PCI cards
  • N+1 power supply redundancy
  • Hot-swappable power supplies
  • Redundant, hot-swappable fan trays
  • Environmental monitoring and fault protection
  • Automatic System Recovery (ASR)
  • Remote Lights Out Management capability
  • Support for disk and network multipathing with automatic failover capability
  • Dual-loop enabled FC-AL mass storage system
  • Error correction and parity checking for improved data integrity
Regulations
Note Meets or exceeds the following requirements:

Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336

Ergonomics EK1-ITB-2000

RFI/EMC EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3

Immunity EN55024/CISPR24

Telecommunications EN300-386

X-ray (for monitors) DHHS 21 Subchapter J; PTB German X-ray Decree

Regulatory markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark

Other Restriction of Hazardous Substances (RoHS) directive 2002/95/EC
Labeled per Waste Electrical and Electronic Equipment (WEEE) Directive
Trade in and Save
Upgrades The Sun Upgrade Advantage Program (UAP) offers trade-in value for qualified Sun and competitive servers toward the purchase of replacement Sun Fire V890 server(s). Whether upgrading one system or consolidating many systems to one, Sun UAP offers the flexibility to trade in and receive credit toward the new Sun system purchased. Upgrades are also available for Sun Fire server system components, including CPU/memory boards and I/O. For more information visit http://www.sun.com/tradeins/offerings/mid.jsp.
Warranty
Hardware support 3 years

Software install 90 days

Call response 8 hours

Delivery Next business day, on-site