Sun Netra T5220 Server

Sun Netra T5220 Server

Get It

From $13,225.00 (US)

Specifications

When the demands of network infrastructure include NEBS certification, you can deploy this server and be confident that you won't outgrow it soon. Scale from four to eight cores of UltraSPARC T2 processing, each with its own floating point unit (FPU). The Sun Netra T5220 server provides expandability and I/O performance with six PCI slots and four Ethernet interfaces.


Key Specifications

  • Up to eight-core 1.2-GHz UltraSPARC T2 processors
  • Up to 64 processing threads
  • 4 MB integrated L2 cache per processor
  • Less than 95W (nominal) power consumption, less than 2W per thread
  • 16 FB-DIMM memory slots (64 GB memory maximum )
Architecture
Processor Up to eight core 1.2-GHz UltraSPARC T2 processors; one processor per system, maximum 64 threads

Main Memory 16 FB-DIMM slots. Up to 64 GB memory (up to 128 GB memory when 8 GB DIMMs are available)
Standard/Integration Interfaces
Network Four 10/100/1000 Mbps Ethernet; up to 2x optional 10 GbE XAUI connections

Expansion Bus Two eight-lane PCIe, two four-lane PCIe, two PCI-X (one full-length/full-height, one half-length/full-height)

USB Two 2.0 USB ports

Virtualization Integrated, open-source, no-cost virtualization technology provides the flexibility and power of 64 virtual systems in a single server

Management Integrated Lights Out Manager

Telecom Features Dry contact alarms

Mass Storage and Media Up to four internal 146 GB SAS drives (2.5 in.)
One slimline DVD-R/W with 2 hard disk drives
Software
Operating system Supports the Solaris OS — beginning with the Solaris 10 OS 8/07

Virtualization Integrated, open-source, no-cost virtualization technology provides the flexibility and power of 64 virtual systems in a single server
Power Supplies
Power Supplies Two 1+1 dedundant DC or AC hot-swappable 650W power supply units
Environment
Operating Temperature 5° C to 40° C (41° F to 104° F), short-term -5° C to 55° C (23° F to 131° F)

Nonoperating Temperature -40° C to 70° C (-40° F to 158° F)

Operating Relative Humidity 5–85%, noncondensing

Short-Term Relative Humidity 5–90%, noncondensing, but not to exceed 0.024 kg water/kg dry air (0.053 lb. water/2.205 lbs. dry air)

Nonoperating Relative Humidity Up to 93%, noncondensing, 40° C (104° F)

Operating Altitude Up to 3,000m (9,850 ft.) at 40° C

Nonoperating Altitude Up to 12,000m (40,000 ft.)

DC Power -48 V DC or -60 V DC

AC Power 100–240 V AC, 50–60 Hz

Declared Acoustics Operating/idling 7.2 B (LwAd, 1 B = 10 dB)

ETSI EN 300019-2-1,2,3, Class 1.2, 2.3, 3.1E
  • Except condensing humidity and rain

NEBS NEBS Level 3 certified by Telcordia

Seismic GR-63-CORE requirements for Earthquake Zone 4
Dimensions and Weight
Height 87.1mm (3.43 in.)

Width (including bezel) 445mm (17.52 in.)

Depth (max., to PSU handles) 526mm (20.71 in.)

Depth (to rear I/O) 501mm (19.72 in.)

Weight (fully configured without PCI cards) 17.5 kg (38.5 lbs.)
Regulations
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all national differences, IEC825-1, 2, and CFR21 part 1040

RFI/EMC EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A

Immunity EN55024/CISPR24, EN61000-3-2, EN61000-3-3

Telecommunications EN300-386

Regulatory Markings CE, FCC, ICES-003, C‑Tick, VCCI, GOST-R, MIC, UL/ cUL, S-Mark, BSMI, CCC

Other Restriction of Hazardous Substances (RoHS) labeled, per WEEE (Waste Electrical and Electronics Equipment) Directive (2002/95/EC)
Warranty
Hardware Support 1 year

Operating System 90-day warranty

Call Response 8 business hours

Delivery Return to Sun

Customer Installable Hardware product Yes