Architecture
|
|
Processor
|
Up to eight core 1.2-GHz UltraSPARC T2 Plus processors; two processor per system, maximum 128 threads
|
|
|
Main Memory
|
Up to 32 FB-DIMM slots. Up to 128 GB memory (up to 256 GB memory when 8GB DIMMs are available)
|
|
Standard/Integration Interfaces
|
|
Network
|
Four 10/100/1000 Mbps Ethernet; up to 2x optional 10 GbE XAUI connections;one RJ-45 serial management port; one 10/100 Mbps Ethernet network management port; one DB-9 serial port
|
|
|
Expansion bus
|
10 PCI slots: 8 PCIe (6x PCI-Express slots for MD2 low profile cards ;
2x PCI-Express slots for full-height, full-length cards ) and 2 PCI-X
slots (133MHz, 3.3V, FL/FH)
|
|
|
USB
|
Four 2.0 USB ports
|
|
|
Virtualization
|
Integrated, open-source, no-cost virtualization technology provides the flexibility and power of 128 virtual systems in a single server
|
|
|
Management
|
Integrated Lights Out Manager
|
|
|
Mass Storage and Media
|
Up to twelve 146 GB SAS disk drives, depending on configuration
One slimline DVD R/W drive
|
|
Software
|
|
Operating system
|
Support Solaris OS beginning with Solaris 10 OS 5/08 with patches 138312-01 and 125952-17
|
|
|
Virtualization
|
Integrated, open-source, no-cost virtualization technology provides the flexibility and power of 128 virtual systems in a single server
|
|
Power Supplies
|
|
Power Supplies
|
Four 2+2 redundant, AC or DC hot-swappable
650 W power supply units
|
|
Environment
|
|
Operating Temperature
|
5° C to 40° C (41° F to 104° F), short-term -5° C to 55° C (23° F to 131° F)
|
|
|
Nonoperating Temperature
|
-40° C to 70° C (-40° F to 158° F)
|
|
|
Operating Relative Humidity
|
5–85%, noncondensing
|
|
|
Short-Term Relative Humidity
|
5–90%,
noncondensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lbs. dry air)
|
|
|
Nonoperating Relative Humidity
|
Up to 93%, noncondensing, 40° C (104° F)
|
|
|
Operating Altitude
|
Up to 3,000m (9,850 ft.) at 40° C
|
|
|
Nonoperating Altitude
|
Up to 12,000m (40,000 ft.)
|
|
|
DC Power
|
-48 V DC or -60 V DC
|
|
|
AC Power
|
100–240 V AC, 50–60 Hz
|
|
|
Declared Acoustics
|
Operating/idling 7.2 B (LwAd, 1 B = 10 dB)
|
|
|
ETSI
|
EN300019-2-1,2,3, Class 1.2, 2.3, 3.1E
(except condensing humidity and rain)
|
|
|
NEBS
|
NEBS Level 3 certified by Telcordia
|
|
|
Seismic
|
GR-63-CORE requirements for
Earthquake Zone 4
|
|
Dimensions and Weight
|
|
Height
|
174.2mm (6.86 in.)
|
|
|
Width (including bezel)
|
445mm (17.5 in.)
|
|
|
Depth (max., to PSU handles)
|
530mm (20.87 in.)
|
|
|
Depth (max., to rear I/O)
|
505mm (19.88 in.)
|
|
|
Weight (fully loaded without PCI cards)
|
33 kg (72.6 lbs.)
|
|
Regulations
|
|
Safety
|
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB
Scheme with all national differences, IEC825-1, 2, and CFR21 part 1040
|
|
|
RFI/EMC
|
EN55022/CISPR22 Class A, FCC CFR47 Part 15
Class A
|
|
|
Immunity
|
EN55024/CISPR24, EN61000-3-2, EN61000-3-3
|
|
|
Telecommunications
|
EN300-386
|
|
|
Regulatory Markings
|
CE, FCC, ICES-003, C‑Tick, VCCI, GOST-R, MIC, UL/cUL, S-Mark, BSMI, CCC
|
|
|
Other
|
Restriction of Hazardous Substances (RoHS) labeled, per WEEE (Waste Electrical and Electronics Equipment) Directive (2002/95/EC)
|
|
Warranty
|
|
Hardware Support
|
1 year
|
|
|
Operating System
|
90-day warranty
|
|
|
Call Response
|
8 business hours
|
|
|
Delivery
|
Return to Sun
|
|
|
Customer Installable Hardware product
|
Yes
|