Solaris Cluster Open Hardware Program

Overview
Sun Cluster and HP X64 ProLiant Servers Interoperability Matrix
HP Servers1 Operating System Cluster Software Max # Nodes VM Software Multi-Path Driver Host Adapters7 SAN Switches HP Storage HP Storage Array Firmware6 Network Interface Controller (NIC)9
  BL280c G6
  BL460c
  BL460c G6
  BL465c
  BL465c G6
  BL480c
  BL490c G6
  BL680c
  BL685c
  BL685c G6

  DL320 G6
  DL360 G5
  DL360 G6
  DL365 G5
  DL370 G6
  DL380 G5
  DL380 G6
  DL385
  DL385 G2
  DL385 G5
  DL385 G6
  DL580 G5
  DL585
  DL585 G2
  DL585 G5
  DL585 G6
  DL785 G5
  DL785 G6
  ML370 G5
Solaris 10 x86 (64 bit) 11/06 - 5/09 SC 3.1 8/2005

SC 3.2 - SC 3.2 1/092
4 Solaris SVM SAN driver bundled in OS for Solaris 10 SG-XPCIE1FC-EM4
SG-XPCIE2FC-EM4
SG-XPCIE1FC-QF4
SG-XPCIE2FC-QF4
SG-XPCI1FC-EM2
SG-XPCI2FC-EM2
SG-XPCI1FC-EM4-Z
SG-XPCI2FC-EM4-Z
SG-XPCI1FC-QF2
SG-XPCI2FC-QF2
SG-XPCI1FC-QF4
SG-XPCI2FC-QF4

"Native" HBAs supported:
Emulex3
QLogic3
HP8
Brocade4
  • SilkWorm 3200 3800 3900 12000

McData4
  • Sphereon 4300 4500
  • Intrepid 6064 6140

Qlogic4

Cisco4

Sun4

HP5
EVA
  3000 Series
  5000 Series

EVA
  4000 Series
  6000 Series
  8000 Series

EVA
  4100
  6100
  8100

EVA
  4400

XP128/XP1024


XP10000/XP12000

XP20000/XP24000

MSA
  2312fc
  2324fc

EVA
  3000 - 4.001
  5000 - 4.001

EVA
  4x00 - 5.100
  6x00 - 5.100
  8x00 - 5.100

EVA
  4100 - 6.110
  6100 - 6.110
  8100 - 6.110

EVA
  4400 - 9.000

XP128/XP1024 21.14.14.00/00

XP10000/XP12000 50.05.06.00/00 60.01.31.00/00

XP2000/XP24000 60.01.68.00/00

MSA2312fc-M110R20
MSA2324fc-M110R20
NC370x
NC371x
NC373x
NC374x
NC380x

NC7782

NC7170

X4445

7280A-2

7281A-2

  BL280c G6
  BL460c
  BL460c G6
  BL465c
  BL465c G6
  BL480c
  BL490c G6
  BL680c
  BL685c
  BL685c G6

  DL320 G6
  DL360 G5
  DL360 G6
  DL365 G5
  DL370 G6
  DL380 G5
  DL380 G6
  DL385
  DL385 G2
  DL385 G5
  DL385 G6
  DL580 G5
  DL585
  DL585 G2
  DL585 G5
  DL585 G6
  DL785 G5
  DL785 G6
  ML370 G5
Solaris 10 x86 (64 bit) 11/06 - 5/09 SC 3.2 - SC 3.2 1/092 4 Solaris SVM SAN driver bundled in OS for Solaris 10 All Network Interface Cards (NICs) supported with Solaris 10 None iSCSI Arrays:
  MSA2312i- M110R20
  MSA2324i- M110R20
MSA2312i- M110R20
MSA2324i- M110R20
NC370x
NC371x
NC373x
NC374x
NC380x

NC7782

NC7170

X4445

7280A-2

7281A-2

  DL320 G6
  DL360 G5
  DL360 G6
  DL365 G5
  DL370 G6
  DL380 G5
  DL380 G6
  DL385
  DL385 G2
  DL385 G6
  DL585
  DL585 G2
  DL585 G5
  DL585 G6
  DL785 G6
Solaris 10 x86 (64 bit) 11/06 - 5/09 SC 3.2 - SC 3.2 1/092 4 Solaris SVM SAN driver bundled in OS for Solaris 10 SG-XPCI8SAS-E-Z
SG-XPCIE8SAS-E-Z

None SAS Arrays:
  MSA2312sa
  MSA2324sa
MSA2312sa-M110R20
MSA2324sa-M110R20
NC370x
NC371x
NC373x
NC374x
NC380x

NC7782

NC7170

X4445

7280A-2

7281A-2

1 See HP website for more information on ProLiant servers: http://www.hp.com/go/solaris and http://www.hp.com/wwsolutions/solaris

2 OS and Volume Manager support details, please refer to: http://wikis.sun.com/display/SunCluster/Release+Notes+Information
SC 3.2 Solaris support for Solaris 10 8/07 (Update 4) requires patch S10x86 / 126107-01.

3 "Native" HBAs supported by Solaris: http://www.sun.com/io_technologies/index.html

4 For the latest Brocade, McData, Qlogic and Sun switch offerings: http://www.sun.com/storagetek/networking.jsp

5 For a complete list of HP switch offerings, please go to: http://h18006.www1.hp.com/storage/saninfrastructure/switches.html

6 Minimum firmware requirement to enable Sun Cluster.

7 HP ships ProLiant servers with the option for PCI-X or PCI-E HBAs. PCI-E version is default unless specified on order by customer.

8 For a list of HP's HBA offerrings, please go to: http://h71028.www7.hp.com/enterprise/cache/589799-0-0-0-121.html and select the option tab.

9 The embedded NC532i and NC326i adapters cannot be used as transport adapters.