System Architecture
|
|
I/O module
|
Dual and single SAS I/O modules
|
|
|
Interfaces/link speeds
|
Three or six 3 Gb/sec SAS ports per tray
|
|
|
Bandwidth
|
Up to 72 Gb/sec total bandwidth:
- 4 (x4-wide) SAS host/uplink ports (48 Gb/sec bandwidth)
- 2 (x4-wide) SAS host/expansion ports (24 Gb/sec bandwidth)
|
|
|
RAID levels
|
HW (with RAID HBA): RAID levels 0, 1, 10, 1E, 5, 6, 50, 5EE, 60
SW (w/Solaris ZFS): RAID levels 0,1,5,6
|
|
|
Drive population
|
Scales from 12 to 24 hard disk drives per tray
|
|
|
Dynamic capacity expansion
|
Twelve to 192 drives, 876 GB to 192 TB
|
|
|
Volume
|
HW (with RAID HBA): 512 TB per LUN
SW (w/Solaris ZFS): Virtually unlimited
|
|
Disk Drives
|
|
Form factor
|
3.5-inch
|
|
|
Interface
|
SAS
SATA
|
|
|
Supported drive types
|
SAS drives:
- 73 GB, 146 GB, 300 GB, 450 GB; 15,000 rpm
- 400 GB 10,000 rpm
SATA II drives:
- 500 GB, 750 GB, 1TB; 7200 rpm
|
|
Supported Platforms
|
|
Servers
|
|
|
Software
|
|
Management software
|
|
|
|
Operating system (OS) support
|
Solaris (SPARC and X64), Red Hat Enterprise Linux, SuSE Linux Enterprise Server, Microsoft Windows Server
|
|
Reliability, Availability and Serviceability
|
|
RAS features
|
- High availability due to redundant, hot-swappable components
- Non-disruptive firmware upgrades
- Non-disruptive component (Major FRU) replacement
- Non-disruptive hot-swappable I/O modules
- Non-disruptive hot-swappable disk drives
- Dual hot-swappable, redundant and load-sharing power supplies/cooling modules
- RAID protection provided by host S/W or H/W (Sun StorageTek SAS RAID HBA)
|
|
|
Remote services
|
|
|
Dimensions
|
|
Height x width x depth
|
6.88 in. x 17.52 in. x 24.02 in. (174.8 mm x 445.0 mm x 610.2 mm) including SAS connector; including thumb screws, depth is 23.24 in. (590.3 mm)
|
|
|
Weight (maximum)
|
110.23 lb. (50 kg)
|
|
Power
|
|
Input voltage
|
88 - 264 VAC
|
|
|
Input frequency
|
47 – 63 Hz
|
|
|
Output power
|
760 W
|
|
|
Power consumption
|
|
|
Operating Environment
|
|
Heat output
|
662 W (2123 BTU/hour)
|
|
|
Temperature
|
35°F to 95°F (0°C to 35°C)
|
|
|
Humidity (non-condensing)
|
20% to 80% maximum
|
|
|
Altitude
|
0 to 9843 feet (3000 meters)
|
|
|
Shock
|
31G +/-5%, with pulse duration of 2.6 ms or less half-sine, bottom side tested only
|
|
|
Vibration
|
0.25 G (peak), 3 to 200 Hz sweep @ ½ octave per minute, bottom side tested only
|
|
Warranty
|
|
Duration
|
Three years — parts exchange
|
|
|
Phone support
|
8 a.m.–5 p.m., Mon.–Fri.
|
|
|
Other
|
Additional support and extended onsite coverage available through Sun System Pack
|
|
Regulations
|
|
Electromagnetic emissions standards
|
- FCC - Class A
- CE - Specific requirements in effect from July 1, 2001
- VCCI - for Japan
- CCC - for China
- BSMI - for Taiwan/CNS/3438
- C-TICK - for Australia and New Zealand
|
|
|
Safety standards
|
- UL/CUL: for U.S. with Canada/UL60950-1
- TUV: for Germany/EN60950-1
- CB (by TUV): IEC60950-1
- BSMI: Taiwan/CNS14336