Sun StorageTek 6140 Array
|
| |
6140 - 2 GB cache
|
6140 - 4 GB cache
|
|
Controller card
|
Dual Fibre Channel RAID controller cards
|
|
|
Cache size (with ECC protection)
|
2 GB data cache
|
4 GB data cache
|
|
|
Host ports
|
Four (SFPs)
|
Eight (SFPs)
|
|
|
Host interfaces/link speeds
|
Switched FC or FC-AL/4 Gb/sec, 2 Gb/sec, 4 Gb/sec
|
|
|
Other interfaces
|
- Two 4 Gb/secor 2 Gb/secFC expansion ports (switched loop)
- Two 6-pin Mini-DIN to 9-pin serial ports
- Four RJ45 10/100 Base-T network connectors
|
|
|
RAID Level
|
0, 1, 3, 5, 1+0 and 6 (p+q)
|
|
|
Cache battery backup
|
Up to 72 hours
|
|
|
Integrated data services/ premium features (optional)
|
- Sun StorageTek Data Snapshot (supports up to 8 snapshots per volume, 512 per array)
- Sun StorageTek Data Volume Copy (optional) (supports up to 8 active copies per volume, 1,024 per array)
- Sun StorageTek Data Replicator software (supports up to 64 replicated volumes)
- Sun StorageTek Storage Domain (supports up to 128 Domains, 6140 - 2 GB cache supports up to 32 only)
|
|
|
Dynamic capacity expansion
|
Five to 64 drives
365 GB to 64 TB
|
Five to 112 drives
365 GB to 112 TB
|
|
|
Expansion tray (FC-SBOD)
|
Up to three expansion trays
|
Up to six expansion trays
|
|
|
Dynamic reconfiguration
|
Volume expansion, RAID migration, capacity
expansion, segment size migration, volume/virtual disk reconfiguration, controller firmware upgrades
|
|
|
Drive depopulation
|
Scales from five to 16 hard disk drives per tray
|
|
|
Volume
|
Up to 1,024
|
Up to 1,024
|
|
|
Global hot spares
|
Unlimited
|
Unlimited
|
|
|
Maximum array capacity
|
64 TB
|
112 TB
|
|
Disk drives
|
|
Form factor
|
3.5 in., low-profile
|
|
|
Interface
|
Dual-ported Fibre Channel
|
|
|
Supported drives/system per tray capacity (raw, unformatted)
|
Fibre Channel drives
- 146 GB 15,000-rpm 4 Gb/sec - 2,336 GB per tray
(3 RU)
- 300 GB 15,000-rpm 4 Gb/sec - 4,800 GB per tray
(3 RU)
- 300 GB 10,000-rpm 2 Gb/sec - 4,800 GB per tray
(3 RU)
- 400 GB 10,000-rpm 4 Gb/sec - 6,400 GB per tray
(3 RU)
SATA-II drives
- 500 GB 7,200-rpm 3 Gb/sec - 8,000 GB per tray
(3 RU)
- 750 GB 7,200-rpm 3 Gb/sec - 12,000 GB per tray
(3 RU)
- 1,000 GB 7,200-rpm 3 Gb/sec - 16,000 GB per tray
(3 RU)
|
|
Host Connectivity
|
|
Multipath driver
|
Sun Traffic Manager for the Solaris OS Veritas DMP, as well as native driver for other operating systems
|
|
Software
|
|
Supported software
|
|
|
|
Management software support
|
- Sun StorageTek Common Array Manager (CAM) software (included)
|
|
Support
|
|
Operating system support
|
- Solaris Operating System 8, 9, 10, and x64
- Microsoft Windows 2000 Server and Advanced Server (SP4)
- Microsoft Windows 2003 Server Standard, Enterprise, and Web editions
- Windows Server 2008
- HP-UX 11.11 and 11.23
- IBM AIX 5.3, 5.4
- Red Hat Linux AS/ES/WS Enterprise Edition 4.0/5.0
- SUSE LINUX LES 9 and 10
- Netware 6 SP5, Netware 6.5 SP3
- VMWare ESX 3.5
The Sun StorageTek 6140 array is fully supported with major host operating systems and multi-path drivers.
|
|
Warranty
|
|
Duration
|
Three years
|
|
|
Phone Support
|
8 a.m.-8 p.m., Mon-Fri
|
|
|
On-Site Service
|
Next business day, 8 a.m.-5 p.m., Mon-Fri
|
|
|
On-Site Response Time
|
Next business day, local business hours
|
|
|
Service upgrade
|
SunSpectrum available
|
|
Dimensions
|
|
Height x width x depth
|
Controller module: 5.1 inches high (12.95 cm) x 17.6 inches wide (44.70 cm) x 22.5 inches deep (57.15 cm)
Expansion module: 5.1 inches high (12.95 cm) x 17.6 inches wide (44.70 cm) x 22.5 inches deep (57.15 cm)
Cabinet: 74 inches (188 cm) x 23.5 inches (59.7 cm) x 39.4 inches (100 cm)
|
|
|
Weight (maximum)
|
40 kg (88 lbs.)
|
|
Power requirements
|
|
AC power
|
Controller module: 3.96 A max. operating at 115 V AC
(90–136 V AC range), 50/60 Hz
2.06 A max. operating at 240 V AC (180–264 V AC range),
50/60 Hz
Expansion module: 4.11 A max. operating at 115 V AC
(90–136 V AC range), 50/60 Hz
1.97 A max. operating at 240 C (180-264 V AC range),
50/60Hz
|
|
|
DC Power
|
Controller module: DC power: 17 A max. operating
(-36 to -72 V DC range)
Expansion module: DC power: 17 A max. operating
(-36 to -72 V DC range)
|
|
Environment
|
|
Operating temperature
|
5° to 40°C (41° to 104°F)
|
|
|
Relative humidity
|
5 to 85 percent noncondensing
|
|
|
Altitude
|
100 ft. (30.5m) below sea level to 9,840 ft. (3,000m)
|
|
|
Shock
|
10 G, 11 ms half-sine
|
|
|
Vibration
|
Random vibration to specified power spectral density
|
|
|
Heat output
|
Controller module: 460 watts (1,571 BTU/hr.)
Expansion module: 444 watts (1,517 BTU/hr.)
|
|
Regulations
|
|
Safety and emissions
|
IEC 60950, EN 60950, UL/CSA 60950, FCC Part 15
(47CFR15B), CISPR 22 (EN55022—RF radiated and
conducted emissions), IEC 61000-3-2, IEC 61000-3-3
|
|
|
Immunity
|
CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC
61000-4-4, IEC 61000-4-5, IEC 61000 4-6, IEC 61000-4-11
|
|
|
Ruggedized
|
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), ETSi EN 300 386
|