No Longer Orderable
Maximum burst I/O rate :
FLX640 disk controller: 100,000 IO/sec
FLX680 disk controller: 200,000 IO/sec
Maximum sustained throughput :
FLX640 disk controller: 390 MB/sec
FLX680 disk controller: 772 MB/sec
Total cache size :
FLX640 disk controller: 2 GB
FLX680 disk controller: 4 GB
Connectivity :
Host interface:
FLX640 disk controller: 2 Gb/sec
FLX680 disk controller: 2 Gb/sec
Host connections :
FLX640 disk controller: 8 FC-AL direct attach and 2 FC-SW SAN attach
FLX680 disk controller: 16 FC-AL direct attach or 4 FC-SW SAN attach
Drive interface :
FLX640 disk controller: 2 Gb/sec
FLX680 disk controller: 2 Gb/sec
Drive connections :
FLX640 disk controller: 2 Fibre Channel
FLX680 disk controller: 4 Fibre Channel
Back to Top
Maximum number of drives :
FLC600 disk array: 40 drives, 20–500 GB blades
FLX640 disk controller: 112 drives, 56-500 GB blades
FLX680 disk controller: 232 drives, 116–500 GB blades
Compatible arrays :
FLX640 disk controller: FLC600
FLX680 disk controller: FLC600
Drive capacity :
FLC600 disk array: 250 GB (7,200 rpm)
FLX640 disk controller: SATA: 250 GB; blade: 500 GB
FLX680 disk controller: SATA: 250 GB; blade: 500 GB
Maximum number of FLC600 arrays :
FLX640 disk controller: 2
FLX680 disk controller: 5
Drive connection :
FLC600 disk array: SATA
Drive interface :
FLC600 disk array: 200 MB/sec per connection
Back to Top
Redundant components :
FLC600 disk array: N/A
FLX640 disk controller: Storage controllers, Fibre Channel drive loops, cache memory, power supplies and cooling fans
FLX680 disk controller: Storage controllers, Fibre Channel drive loops, cache memory, power supplies and cooling fans
Hot-swap components : FLC600 disk array: N/A
FLX640 disk controller: 500 GB blades, storage controllers, power supplies, cooling fans and battery backup
FLX680 disk controller: 500 GB blades, storage controllers, power supplies, cooling fans and battery backup
High-availability features :
FLC600 disk array: N/A
FLX640 disk controller: Automatic drive failure detection and rebuild using global hot spare drives, cache battery backup
FLX680 disk controller: Automatic drive failure detection and rebuild using global hot spare drives, cache battery backup
RAID levels supported :
FLC600 disk array: N/A
FLX640 disk controller: 5
FLX680 disk controller: 5
Back to Top
Supported operating systems :
FLC600 disk array: N/A
FLX640 disk controller: Windows Server 2003, Solaris, AIX, Linux
FLX680 disk controller: Windows Server 2003, Solaris, AIX, Linux
Back to Top
Storage management software :
FLC600 disk array: N/A
FLX640 disk controller: Web interface or CLI
FLX640 disk controller: Web interface or CLI
Standard features :
FLC600 disk array: N/A
FLX640 disk controller: Online storage management, storage class manager, over subscription, advanced fault management, storage partitions (up to 255 hosts)
FLX640 disk controller: Online storage management, storage class manager, over subscription, advanced fault management, storage partitions (up to 255 hosts)
Back to Top
Height
FLC600 disk array: 7.0 in (17.78cm)
FLX640 disk controller: 7.0 in (17.78cm)
FLX680 disk controller: 7.0 in (17.78cm)
Depth
FLC600 disk array: 35.0 in (88.9 cm)
FLX640 disk controller: 35.0 in (88.9 cm)
FLX680 disk controller: 35.0 in (88.9 cm)
Width
FLC600 disk array: 17.68 in (44.9 cm)
FLX640 disk controller: 17.68 in (44.9 cm)
FLX680 disk controller: 17.68 in (44.9 cm)
Unit Height :
FLC600 disk array: 4U* (includes housing for 20 blades)
FLX640 disk controller: 4U* (includes housing for 16 blades)
FLX680 disk controller: 4U* (includes housing for 16 blades)
*Rack space is measured in height and expressed as a "U". One U is 1.75 in (4.45 cm) in height.
Weight
FLC600 disk array: 150.0 lb (68 kg)
FLX640 disk controller: 150.0 lb (68 kg)
FLX680 disk controller: 150.0 lb (68 kg)
Back to Top
Temperature
FLC600 disk array: +50° to +104° F (+10° to +40° C)
FLX640 disk controller: +50° to +104° F (+10° to +40° C)
FLX680 disk controller: +50° to +104° F (+10° to +40° C)
Relative Humidity
(non-condensing):
FLC600 disk array: 10% to 90%
FLX640 disk controller: N/A
FLX680 disk controller: N/A
Altitude
FLC600 disk array:
Maximum 8,000 ft (2,438.4 m) @ 104° F (40° C)
Maximum 10,000 ft (3,048 m) @ 98.6° F (37° C)
FLX640 disk controller: N/A
FLX680 disk controller: N/A
Temperature gradient:
FLC600 disk array: 20° C/hr
FLX640 disk controller: N/A
FLX680 disk controller: N/A
Heat dissipation:
FLC600 disk array: N/A
FLX640 disk controller: N/A
FLX680 disk controller: 2,422 Btu/hr (dual line cord, combined operation to both)
Back to Top
International :
FLC600 disk array: N/A
FLX640 disk controller: 240 V, 10 A, power connection as required
FLX680 disk controller: 240 V, 10 A, power connection as required
U.S. and Japan : N/A
FLX640 disk controller: 120 V, 15 A, NEMA 5–15
FLX680 disk controller: 120 V, 15 A, NEMA 5–15
Input requirements :
FLC600 disk array: 50 to 60 Hz, 100 to 240 VAC, single phase
FLX640 disk controller: N/A
FLX680 disk controller: N/A
Power factor :
FLC600 disk array: 0.89 minimum
FLX640 disk controller: N/A
FLX680 disk controller: N/A
Back to Top
Electromagnetic compliance :
FLC600 disk array: FCC (47 CFR 15, Subpart B) Class A CE (EN55022 Class A) VCCI (CISPR 22) Class A
FLX640 disk controller: FCC (47 CFR 15, Subpart B) Class A CE (EN55022 Class A) VCCI (CISPR 22) Class A
FLX680 disk controller: FCC (47 CFR 15, Subpart B) Class A CE (EN55022 Class A) VCCI (CISPR 22) Class A
Safety :
FLC600 disk array: EN 60950
FLX640 disk controller: EN 60950
FLX680 disk controller: EN 60950
Back to Top
>