Sun StorageTek 2530 Array
|
|
Controller card
|
Dual and single SAS RAID controller
|
|
|
Cache size (with ECC protection)
|
512 MB/controller to 1 GB/system
|
|
|
Host interfaces/link speeds
|
Three to six 3 Gb/sec SAS host ports per controller tray
|
|
|
Other interfaces (per dual controller tray)
|
Up to two 10/100 Base-T Ethernet ports
Up to two nine-pin RS-232 serial ports per dual controller tray
|
|
|
RAID levels
|
0, 1, (1+0), 3, 5 and 6 (p+q)
|
|
|
Cache battery backup
|
Up to 72 hours (depending on cache size)
|
|
|
Integrated data services
|
- Sun StorageTek Data Snapshot (optional) - supports four snaps per volume, 128 per array
- Sun StorageTek Enhanced Data Snapshot (optional) - supports eight snaps per volume, 128 per array
- Sun StorageTek Volume Copy (optional)
- Sun StorageTek Storage Domains - two domains included; (optional) - four, eight, sixteen or thirty two
|
|
|
Dynamic capacity expansion
|
Five to 48 drives - 730 GB to 48.0 TB
|
|
|
Expansion tray
|
Up to three expansion trays
|
|
|
Drive depopulation
|
Scales from five to 12 hard disk drives per tray
|
|
|
Volume
|
Up to 256 (32 per host)
|
|
|
Global hot spares
|
Up to 30
|
|
|
Maximum array capacity
|
21.6 TB (450 GB SAS drives)
48.0 TB (1 TB SATA drives)
|
|
Disk drives - Supported drives/system per tray capacity: raw, unformatted
|
|
Form factor
|
3.5 in., low-profile
|
|
|
Interface
|
Dual-ported SAS
|
|
|
SAS drives
|
146 GB, 15,000-rpm 3 Gb/sec, 1.75 TB per tray
300 GB, 15,000-rpm 3 Gb/sec, 3.6 TB per tray
450 GB, 15,000-rpm 3 Gb/sec, 5.4 TB per tray
400 GB 10,000-rpm 3 Gb/sec, 4.8 TB per tray
|
|
|
SATA–ll drives
|
500 GB, 7,200-rpm 3 Gb/sec, 6.0 TB per tray
750 GB, 7,200-rpm 3 Gb/sec, 9.0 TB per tray
1.0 TB 7,200-rpm 3 Gb/sec,12.0 TB per tray
|
|
Supported software
|
|
Supported software
|
|
|
Management software support
|
|
Management software support
|
Sun StorageTek Common Array Manager Software
|
|
Operating system support
|
|
Operating system support
|
- Solaris Operating System 10 and x86
- Microsoft Windows 2003, 2008
- SUSE Linux 9.0, 10.0
- Red Hat Enterprise Linux 4.0, 5.0
|
|
Host connectivity
|
|
Host/HBA/FC switches
|
All HBAs supported in SAN 4.4.12
|
|
Warranty
|
|
Duration
|
Three years (parts only)
|
|
|
Phone support
|
8 a.m.-8 p.m., Mon-Fri
|
|
|
Replacement parts
|
Return to Sun
|
|
Dimensions
|
|
Height x width x depth
|
86.1 mm (3.39 in.) x 448.6 mm (17.66 in.)
x 540 mm (21.26 in.)
|
|
|
Weight (maximum)
|
59.55 lbs
|
|
Power requirements
|
|
AC power
|
515 W (+ 5 V @ 19 A/+12 V @ 35 A )
|
|
|
DC power
|
17 A Max Operating (-42 to -60 VDC)
|
|
Environmental (operating)
|
|
Operating temperature
|
10-40° C (50-104° F) without battery 10-35° C (50-95° F) with battery
|
|
|
Operating altitude
|
68.3 kPa (3,200m), 40° C, four-hour dwell[1]
|
|
|
Operating shock
|
5.5 Gs, 11ms, half-sine, 10 shocks per direction, all six directions
|
|
|
Operating vibration
|
All three axes: 0.25 Gs, 5 to 500 Hz, swept-sine, five sweep cycles, one octave per minute
|
|
|
Heat output
|
460 watts (1,571 BTU/hr.)
|
|
Environmental (non–operating)
|
|
Temperature (storage)
|
-10 to 50° C (-14 to 122° F) without battery -10° to 45° C (-14° 113° F) with battery (three-month maximum
|
|
|
Temperature (transit)
|
-40 to 60° C (-40 to 140° F) without battery
-20 to 60° C (-4 to 140° F) with battery (one-week maximum)
|
|
|
Humidity (storage)
|
10-90%, max dew point is 26° C (79°F), 10% per hour gradient
|
|
|
Humidity (transit)
|
5-95%, max dew point is 26° C (79°F), 10% per hour gradient
|
|
|
Altitude
|
18.8 kPa (12,200m), oC, four-hour dwell[1]
|
|
|
Shock
|
20 G, 8.0 msec square wave in each direction along x, y, and z axes
|
|
|
Vibration
|
All three axes: 1.2 Gs, 5 to 500 Hz, swept-sine, five sweep cycles, one octave per minute
|
|
Regulations
|
|
Safety and emissions
|
FCC Class A VCCI Class A EN55022 Class A
EN 55024 UL BSM C-Tick RoHS WEEE
|
|
|
NTS certified
|
NEBS Level 3
|