Standard Interfaces
|
|
Host interface
|
320 MB SCSI LVD
|
|
|
Drives
|
320 MB SCSI 3.5 in. low profile
|
|
|
Supported drives
|
73 GB 10K rpm; 73 GB 15K rpm; 146 GB 10K rpm; 146 GB 15K rpm; 300 GB 10K rpm; 300 GB 15K rpm
|
|
|
Maximum number of host ports
|
- 3 x 320 MB SCSI host ports (without expansion trays);
- 2 x 320 MB SCSI host ports (with 1 expansion tray);
- 1 x 320 MB SCSI host port (with 2 expansion trays)
|
|
|
Maximum cable length
|
12 m
|
|
Tray (12 HDDs) and RAID Array (36 HDDs) Maximum Raw Storage Capacities
|
|
73 GB 10K rpm and 15K rpm HDDs
|
876 GB per 2U tray; expandable to 2.6 TB per RAID array
|
|
|
146 GB 10K rpm and 15K rpm HDDs
|
1.72 TB per 2U tray; expandable to 5.2 TB per RAID array
|
|
|
300 GB 10K rpm and 15K rpm HDDs
|
3.60 TB per 2U tray; expandable to 10.8 TB per RAID array
|
|
RAID Controller Card
|
|
RAID configurations
|
Per Tray: JBOD/Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers
|
|
|
RAID levels
|
0, 1, 1+0, 3, 5, 3+0, and 5+0
|
|
|
Max. LUNS
|
Up to 128 per RAID array
|
|
|
Max. local and/or global hot spares
|
Up to 20 (RAID set and disk quantity dependent) per RAID array
|
|
|
Cache size (read and write)
|
512 MB per controller
|
|
|
Cache battery backup
|
Up to 72 hours
|
|
|
Cache write policy (user configurable)
|
Write Back—default; Write Through—default for single controller or on battery/controller frame
|
|
|
Cache selectable block sizes
|
32K (random file transfer); 128K (sequential file transfer)
|
|
|
Included Management software
|
Sun StorageTek Configuration Service; Sun StorageTek Diagnostic Reporter software
Vibration 0.2 G, 5–500 Hz, swept-sine 1.0 G, 5–500 Hz, swept-sine
|
|
|
Optional supported software
|
Sun StorageTek Enterprise Storage Manager, Sun StorageTek Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorageTek Resource Management, Sun StorageTek Utilization, and Sun StorageTek Performance Suites
|
|
Support Host Platforms
|
|
Supported Hosts Servers
|
All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers
|
|
|
Supported HBAs
|
Note: All non-Sun host bus adapters supported by third-party vendor.
|
|
|
Sun Solaris Operating Systems 8, 9, 10 (SPARC-based)
|
HBAs: SG-XPCI2SCSI-LM320, (X)6758A; (X)2222A; (X)4422A
|
|
|
Sun Solaris x86 9, 10
|
HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSI-LM320;
LSI Logic LSI22320-R
|
|
|
Red Hat Linux AS3.0
|
HBAs: (Sun Fire V60x, V65x, V20z, V40z), X9265A; SG-XPCI2SCSI-LM320;
LSI Logic LSI22320-R
|
|
|
Novell SuSE Linux SLES 9
|
HBA: SG-XPCI2SCSI-LM320
|
|
|
MS Windows NT EE 4.0/2000/2003
|
HBAs: X9265A; SG-XPCI2SCSI-LM320; LSI Logic LSI22320-R
|
|
|
Novell NetWare 5.1, 6.0, 6.5
|
HBAs: Adaptec 39160; Adaptec 39320
|
|
|
HP-UX 11i
|
HBA: HP A6829A
|
|
|
IBM-AIX 5.1L
|
HBA: IBM SYM53C1010
|
|
Reliability, Availability, Serviceability (RAS)
|
|
RAS
|
- Hot-swap RAID controllers with battery-backed mirrored 512 MB cache, (with dual RAID controllers)
- 1 x 320 MB SCSI host port (with 2 expansion trays)
Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
- Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
- Hot-swap, redundant electrically-isolated redundant cooling fans
- Non-disruptive firmware upgrades (with dual RAID controllers via SSCS)
|
|
Electrical Requirements
|
|
Wattage
|
420W each (Dual Hot-Swap Redundant Power Supplies)
|
|
|
AC Voltage
|
100 to 240 VAC, single phase
|
|
|
AC Power requirement
|
90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
|
|
|
AC Current per input
|
100 to 240 VAC, 50 to 60 Hz, 5.0–7.1A
|
|
|
DC Voltage
|
–48 or –60 VDC, 18A
|
|
|
DC Power requirement
|
–36 to –75 VDC
|
|
|
DC Current per input
|
–48 or –60 VDC, 18A
|
|
Environment
|
| |
|
Temperature
|
- Operating: 5°C to 40°C (41°F to 104°F)
- Non-operating: –40°C to 65°C (–40°F to 149°F)
|
|
|
Humidity (non-condensing)
|
- Operating: 10% to 90% relative to 38°
- Non-operating: 0% to 90% relative to 27°C
|
|
|
Altitude
|
- Operating: –30m to 3048m (–100 to 10,000 ft.)
- Non-operating: –30m to 12,192m (–100 to 40,000 ft.)
|
|
|
Shock
|
- Operating: 5.0 G, 11-ms, half-sine
- Non-operating: 15.0 G, 11-ms, half-sine
|
|
|
Vibration
|
- Operating: 0.2 G, 5–500 Hz, swept-sine
- Non-operating: 1.0 G, 5–500 Hz, swept-sine
|
|
|
Noise
|
LWAD = 6.6 bels;
LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C.
|
|
Regulations
|
|
Safety
|
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000,
IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B,
CISPR 22 55022:1998 Class B, ICES-003
|
|
|
Emissions
|
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
|
|
|
Harmonics
|
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
|
|
|
Immunity
|
CSIPR 24 EN 55024
|
|
|
Ruggedized
|
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
|
|
|
Restriction of Hazardous Substances
|
European Union (EU) Directive 2002/95/EC, invoking the "lead-in-solder"
exemption, Article 4(1) paragraph 7.
|
|
Dimensions and Weight
|
|
Dimensions (Height, Width, Depth)
|
H: 8.8 cm (3.5 in.; 2RU); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)
|
|
|
Weight (Fully Populated)
|
22.7 kg (50 lb.)
|
|
Warranty
|
|
Two year
|
Sun two-year standard warranty,
(1st year on site, 2nd year return to depot)
|
|
|
Service upgrades
|
SunSpectrum service upgrades are available
|