Standard Interfaces
|
|
Host interface
|
2 Gb Fibre Channel
|
|
|
Drives
|
3.5 in. low profile
|
|
|
Supported drives
|
Dual-ported active- active 2 Gb Fibre Channel
73 GB 15K rpm; 146 GB 10K rpm, 146 GB 15K rpm, 300 GB 10K rpm, 300 GB 15K rpm
|
|
|
Maximum number of host ports
|
Dual RAID controllers: 8x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays
|
|
|
Maximum cable length
|
250 m
|
|
FC Tray (12 HDDs) and FC RAID Array (108 HDDs) Maximum Raw Storage Capacities
|
|
73 GB 15K rpm HDDs
|
876 GB per 2U tray; expandable to 7.8 TB per RAID array
|
|
|
146 GB 10K rpm and 15K rpm HDDs
|
1.7 TB per 2U tray; expandable to 15.7 TB per RAID array
|
|
|
300 GB 10K rpm and 15K rpm HDDs
|
3.6 TB per 2U tray; expandable to 32.4 TB per RAID array
|
|
FC Tray (12 HDDs) and FC/SATA RAID Array (108 HDDs) Maximum Raw Storage Capacities
|
|
12x300 GB FC + 96x500 GB SATA
|
51.6 TB max per RAID array. FC & SATA expansion trays may be mixed
|
|
RAID Controller Card
|
|
RAID configurations
|
Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers
|
|
|
RAID levels
|
0, 1, 1+0, 3, 5, 3+0, and 5+0
|
|
|
Max. LUNS
|
Up to 1,024 per RAID array
|
|
|
Max. LUN sizes and max. number of logical drives
|
Firmware 4.11 and below: Max. 2 TB LUN size; 8 logical drives max.
Firmware 4.12 and above: Max. 16 TB LUN size; 32 logical drives max.
|
|
|
Max. local and/or global hot spares
|
Up to 20 (RAID set and disk quantity dependent) per RAID array
|
|
|
Cache size (read and write)
|
1 GB per controller
|
|
|
Cache battery backup
|
Up to 72 hours
|
|
|
Cache write policy
|
Write Back—default; Write Through—user configurable
|
|
|
Cache selectable block sizes
|
32K (random file transfer); 128K (sequential file transfer)
|
|
|
Included Management software
|
Sun StorageTek Configuration Service software; Sun StorageTek support
Diagnostic Reporter software
|
|
|
Optional supported software
|
Sun StorageTek Enterprise Storage Manager, Sun StorageTek
Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS
Volume Manager including DMP, Sun Logical Volume Manager for
the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris
8 Operating System, Sun StorageTek Resource Management, Sun StorageTek
Utilization, and Sun StorageTek Performance Suites
|
|
Supported Host Platforms
|
|
Supported Host Servers
|
All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire
x86-based servers; x86-based (Intel and AMD) third-party servers;
IBM RISC-based servers; HP RISC-based servers
|
|
|
Supported host bus adapters
|
- Sun Solaris (8, 9, 10): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
- Sun Solaris x86 10: X9279A (Sun Fire V20z and V40z servers)
- MS Windows/Red Hat Linux/Novell SuSE Linux/Novell Netware: QLA23XX 2 Gb FC PCI*
- HP-UX 11.0 and 11i: Emulex LP9XXX 2 Gb FC PCI* and compatible
- IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2 Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor
|
|
Reliability, Availability, Serviceability (RAS)
|
|
RAS
|
- Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
- Hot-swap RAID controllers with battery-backed mirrored 1 GB cache, (with dual RAID controllers)
- Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
- Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
- Hot-swap, redundant electrically-isolated redundant cooling fans
- Local and global hot sparing
|
|
Electrical Requirements
|
|
Wattage
|
420W each (Dual Hot-Swap Redundant Power Supplies)
|
|
|
AC Voltage
|
100 to 240 VAC, single phase
|
|
|
AC Power requirement
|
90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)
|
|
|
AC Current per input
|
100 to 240 VAC, 50 to 60 Hz, 5.0–7.1A
|
|
|
DC Voltage
|
–48 or –60 VDC, 18A
|
|
|
DC Power requirement
|
–36 to –75 VDC
|
|
|
DC Current per input
|
–48 or –60 VDC, 18A
|
|
Environment
|
|
Temperature
|
- Operating: 5°C to 40°C (41°F to 104°F)
- Non-operating: –40°C to 65°C (–40°F to 149°F)
|
|
|
Humidity (non-condensing)
|
- Operating: 10% to 90% relative to 38°C
- Non-operating: 0% to 90% relative to 27°C
|
|
|
Altitude
|
- Operating: –30 m to 3048 m (–100 to 10,000 ft.)
- Non-operating: –30 m to 12,192 m (–100 to 40,000 ft.)
|
|
|
Shock
|
- Operating: 5.0 G, 11-ms, half-sine
- Non-operating: 15.0 G, 11-ms, half-sine
|
|
|
Vibration
|
- Operating: 0.2 G, 5–500 Hz, swept-sine
- Non-operating: 1.0 G, 5–500 Hz, swept-sine
|
|
|
Noise *
|
- Operating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C.
|
|
Regulations - Meets or exceeds the following requirements:
|
|
Safety
|
UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000,
IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B,
CISPR 22 55022:1998 Class B, ICES-003
|
|
|
Emissions
|
VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark
|
|
|
Harmonics
|
IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001
|
|
|
Immunity
|
CSIPR 24 EN 55024
|
|
|
Ruggedized
|
NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386
|
|
|
Restriction of Hazardous Substances
|
European Union (EU) Directive 2002/95/EC, invoking the "lead-in-solder"
exemption, Article 4(1) paragraph 7.
|
|
Dimensions and Weight
|
|
Dimensions (Height, Width, Depth)
|
H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 53.3 cm (21 in.)
|
|
|
Weight (Fully Populated)
|
22.7 kg (50 lb.)
|
|
Warranty
|
|
Two year
|
Sun two-year standard warranty,
(1st year on site, 2nd year return to depot)
|
|
|
Service upgrades
|
SunSpectrum service upgrades are available
|