Date: 26-Nov-2009   URL: www.sun.com/storage/disk_systems/workgroup/3511/specs.xml

Sun StorageTek 3511 SATA Array

Specifications

No Longer Orderable

The Sun StorageTek 3511 SATA Array provides massively expandable, fully fault tolerant storage capacity for secondary and near line storage applications. The Sun StorageTek 3511 FC array is ideal for such secondary and near-line storage computing environments such as data repositories that typically require high capacity but without the utilization and access characteristics normally associated with primary storage applications.


Standard Interfaces
Host interface 2 Gb Fibre Channel

Drives 3.5 in. low profile

Supported drives Dual-ported 1.5 Gb/sec Serial ATA with active-active loops, 250 GB, 500 GB 7200 rpm SATA

Maximum number of host ports Dual RAID controllers: 12x2 Gb Fibre Channel host ports (no expansion); 6x2 Gb Fibre Channel with expansion trays

Maximum cable length 250 m
Tray (12 HDDs) and RAID Array (108 HDDs) Maximum Raw Storage Capacities
250 GB 7200 rpm HDDs 3 TB per 2U tray; expandable to 18 TB per RAID array

500 GB 7200 rpm HDDs 6 TB per 2U tray; expandable to 54 TB per RAID array
RAID Controller Card
RAID configurations Expansion (no controller); single RAID controller; dual (mirrored) RAID controllers

RAID levels 0, 1, 1+0, 3, 5, 3+0, and 5+0

Max. LUNS Up to 1,024 per RAID array

Max. LUN sizes and max. number of logical drives

Firmware 4.11 and below: Max. 2 TB LUN size; 8 logical drives max.

Firmware 4.11 and above: Max. 16 TB LUN size; 32 logical drives max.

Max. local and/or global hot spares Up to 20 (RAID set and disk quantity dependent) per RAID array

Cache size (read and write) 1 GB per controller

Cache battery backup Up to 72 hours

Cache write policy Write Back—default; Write Through—user configurable

Cache selectable block sizes 32K (random file transfer); 128K (sequential file transfer)

Included Management software Sun StorageTek Configuration Service software; Sun StorageTek support Diagnostic Reporter software

Optional supported software Sun StorageTek Enterprise Storage Manager, Sun StorageTek Traffic Manager, Sun Cluster 3, VERITAS NetBackup and VERITAS Volume Manager including DMP, Sun Logical Volume Manager for the Solaris 9 Operating System, Sun Solstice DiskSuite for the Solaris 8 Operating System, Sun StorageTek Resource Management, Sun StorageTek Utilization, and Sun StorageTek Performance Suites
Supported Host Platforms
Supported Host Servers All Sun Enterprise, Netra, and Sun Fire SPARC-based and Sun Fire x86-based servers; x86-based (Intel and AMD) third-party servers; IBM RISC-based servers; HP RISC-based servers

Supported host bus adapters
  • Sun Solaris Operating Systems 8, 9, 10 (SPARC-based): X6727A, X6767A, X6768A, SG-XPCI1FC-QF2, SG-XPCI2FC-QF2, SG-XPCI1FC-JF2, SG-XPCI2FC-JF2
  • Sun Solaris x86 10: X9279A (Sun Fire V20Z and V40z servers)
  • Red Hat Linux, Enterprise Edition, 32b 64b; Novell SuSE Linux Enterprise server 8; Novell SuSE Linux 9: QLA23XX 2Gb FC PCI*
  • MS Windows NT EE 4.0/2000/2003 server/Novell NetWare 5.1, 6.0, 6.5: QLA23XX 2Gb FC PCI*
  • HP-UX 11.0 and 11i: Emulex LP9XXX 2Gb FC PCI* and compatible
  • IBM-AIX 4.3.3 and 5.1L (32 and 64 bit): Emulex LP9XXX 2Gb FC PCI* and compatible
*Note: All non-Sun host bus adapters supported by third-party vendor
Reliability, Availability, Serviceability (RAS)
RAS
  • Non-disruptive controller firmware upgrades using dual RAID controllers via SSCS
  • Hot-swap RAID controllers with battery-backed mirrored 1 GB cache, (with dual RAID controllers)
  • Up to twelve hot-swap disk drives per RAID array tray and per expansion tray
  • Dual hot-swap, redundant, load-sharing power supplies with dual independent AC inputs
  • Hot-swap, redundant electrically-isolated redundant cooling fans
  • Local and global hot sparing
Electrical Requirements
Wattage 420W each (Dual Hot-Swap Redundant Power Supplies)

AC Voltage 100 to 240 VAC, single phase

AC Power requirement 90 to 132 VAC, 180 to 264 VAC (47 to 63 Hz)

AC Current per input 100 to 240 VAC, 50 to 60 Hz, 5.0–7.1A

DC Voltage –48 or –60 VDC, 18A

DC Power requirement –36 to –75 VDC

DC Current per input –48 or –60 VDC, 18A
Environment
Temperature
  • Operating: 5°C to 40°C (41°F to 104°F)
  • Non-operating: –40°C to 65°C (–40°F to 149°F)

Humidity (non-condensing)
  • Operating: 10% to 90% relative to 38°C
  • Non-operating: 0% to 90% relative to 27°C

Altitude
  • Operating: –30m to 3048m(–100 to 10,000 ft.)
  • Non-operating: –30m to 12,192m(–100 to 40,000 ft.)

Shock
  • Operating: 5.0 G, 11-ms, half-sine
  • Non-operating: 15.0 G, 11-ms, half-sine

Vibration
  • Operating: 0.2 G, 5–500 Hz, swept-sine
  • Non-operating: 1.0 G, 5–500 Hz, swept-sine

Noise *
  • Operating: LWAD = 6.6 bels
*LWAD (1 bel = 10 dB) Declared noise emissions in accordance with ISO 9296, measured at 23°C.
Regulations - Meets or exceeds the following requirements:
Safety UL listed UL 60950:2000, CSA-C22.2 No. 60950-00, EN 60950:2000, IEC 60950, TUV, CB Scheme, GOST-R Mark; S-Mark, FCC Part 15 Class B, CISPR 22 55022:1998 Class B, ICES-003

Emissions VCCI Class B, EN AS/NZS 3548:1996, BSMI CNS 13438 Class B, S Mark

Harmonics IEC 61000-3-2:2000, IEC1000-3-3:1995/A1:2001

Immunity CSIPR 24 EN 55024

Ruggedized NEBS Level 3 (GR-63-CORE; GR-1089-CORE), MIL-STD-810F, ETSI EN 300 386

Restriction of Hazardous Substances Expansion trays compliant under spare parts exemption only.
Dimensions and Weight
Dimensions (Height, Width, Depth) H: 8.8 cm (3.5 in.; 2U); W: 44.7 cm (17.6 in.); D: 54.5 cm (21.5 in.)

Weight (Fully Populated) 26.8 kg (59.1 lb.)
Warranty
Two year Sun two-year standard warranty, (1st year on site, 2nd year return to depot)

Service upgrades SunSpectrum service upgrades are available
 
 
Copyright 2004-2009 Sun Microsystems, Inc.