Interface
|
|
Speed
|
133-MHz, 32-bit PCI-X 1.0
|
|
|
Voltage
|
Only 3.3 V bus is supported
|
|
|
Compliance
|
Conforms to PCI-X Addendum rev. 1.0a, PCI
Local Bus Specification rev. 2.2, PCI Hot Plug
Specification 1.0, PCI Bus Power
Management Interface Specification rev 1.1
|
|
Fibre Channel
|
|
Speed
|
200 MB/sec maximum at half-duplex, 400
MB/sec maximum at full-duplex (2 Gb/sec speed
only)
|
|
|
Compliance
|
Second Generation FC Generic Services
Definition (FC-GS-2), Third Generation FC
Generic Services Definition (FC-GS-3), Fibre
Channel-Physical and Signaling Interface
(FC-PH), SCSI-3 Fibre Channel Protocol (SCSI
FCP), Fibre Channel-Arbitrated Loop-2 (FC-AL
2), Fibre Channel-Private Loop Direct Attach
Technical Report (FC-PLDA), Fibre Channel
Framing and Signaling (FC-FS)
|
|
|
Topology
|
FC-AL, FC-AL-2, switched fabric (F-Port)
|
|
|
Class of service
|
Class 3 Fibre Channel service
|
|
|
Protocol
|
SCSI (FCP), tape (FCP-2)
|
|
Logins and Exchanges
|
|
Logins & exchanges
|
Up to 16 total logins in private loop (FC
AL/FC-AL-2) topology, 8 (target) logins in
fabric (F-Port connect) topology, and up to
64 FCP/FCP-2 exchanges
|
|
|
FC frame size
|
2K fixed
|
|
|
Buffer credits
|
2 credits issued
|
|
Physical
|
|
Ports
|
One
|
|
|
LEDs
|
Two (with beacon support)
|
|
|
Media
|
Multimode optic
|
|
|
Optics
|
Short wave laser
|
|
|
Form factor
|
Low-profile MD1: 11.99 cm to 6.44 cm
(4.721" to 2.536")
|
|
|
Bracket size
|
Standard size, with optional low profile size
|
|
|
Connectors
|
LC-style connector that supports non-OFC,
multimode fibre optic cabling using a small
form factor optical transceiver module
|
|
|
Power consumption
|
~ 5.0 watts
|
|
Environment
|
|
Airflow
|
0 lf/m
|
|
|
Temperature
|
Operating: 0°C/32°F to 55°C/131°F
Storage: –20°C/–4°F to 70°C/158°F
|
|
|
Humidity
|
Relative (non-condensing): 10% to 90%
Storage: 5% to 95%
|
|
|
Distance
|
2 Gb/sec: 300 meters 50/125 µm Fibre, 150
meters 62.5/125 µm Fibre
|
|
|
Cable
|
50/125 µm multimode Fibre
62.5/125 µm
multimode Fibre
|
|
|
Multi-switch fabric
|
Supports up to two switches between the
server and a storage peripheral
|
|
Supported Operating Systems
|
|
Operating systems
|
Solaris 10 x64
Red Hat RHEL 3.0
SUSE SLES 8
SUSE SLES 9
Windows Server 2000
Windows Server 2003
|
|
Supported Server Platforms
|
|
Server platforms
|
Sun Fire x4100
Sun Fire x4200
Sun Fire V40z
Sun Fire V20z
|
|
External Storage Options
|
|
Workgroup Storage
|
|
|
|
Tape Backup and Restore
|
- Sun StorageTek L25 FC
- Sun StorageTek L100 FC
|
|
Agency Approvals – Product Safety
|
|
US/Canada
|
UL, cUL; UL60950-1
CSA C22.2 No.6950
Class 1 Laser Product per DHHS 21CFR J
|
|
|
Europe
|
73/23/ECC Low Voltage Directive, TUV
EN60950-1: 2001
EN60825-1: 1994+A1+A2, EN60825-2: 1994
+A1US FCC Part 15, Class A
|
|
|
Canada
|
Industry Canada ICES-003, Class A
|
|
|
Europe
|
89/336/EEC EMC Directive CE Mark,
EN55022: 1998 /CISPR22: 1997,
Class A, EN55024: 1998, EN61000-3-2: 2000,
EN61000-3-3: 2001; A1:2001
|
|
|
Japan
|
VCCI, Class A
|
|
|
Taiwan
|
CNS 13438 Class A
|
|
|
New Zealand/Australia
|
AS/NZS 3548 Class A Korea MIC Class A
|