Systems Architecture
|
|
Port speed
|
4, 2, and 1 Gb/sec autosensing with 4 Gb/sec of dedicated bandwidth per port and 10 Gb/sec of dedicated bandwidth for 10 Gb/sec ports
|
|
|
Buffer credits
|
Up to 64 for a group of 4 ports, with a default of 16 buffer credits per port for the 4 Gb/sec ports and 64 buffer credits per 10 Gb/sec port
|
|
|
Ports per chassis
|
Up to 32 4 Gb/sec ports and 2 10 Gb/sec ports:
- Base configuration with 24 ports
- Additional ports in 8-port increment with the port activation license for 4 Gb/sec ports
- Two 10 Gb/sec ports with the 10 Gb/sec port license
|
|
|
PortChannel
|
Up to 16 ports in a PortChannel
|
|
|
Fabric services
|
Name server
Registered state change notification (RSCN)
Login services
Broadcast
In-order delivery
Name-server zoning
|
|
|
Advanced services
|
N-port ID virtualization
VSANs
PortChannels
FICON protocol integration
|
|
|
Security
|
VSANs
Zoning
- Hardware-enforced zoning
- Logical-unit-number (LUN) zoning and read-only zones
FC-SP for host-to-switch and switch-to-switch authentication
Port security
Management access
|
|
Management
|
|
Access methods
|
Out-of-band 10/100 Ethernet port
EIA/TIA-232 serial console port
In-band IP over Fibre Channel
|
|
|
Access protocols
|
CLI
SNMP
SMI-S
|
|
|
Security
|
RBACL using RADIUS or TACACS+ authentication, authorization, and accounting (AAA) functions
VSAN-based roles
SSHv2
SNMPv3
|
|
|
Management applications
|
Cisco MDS 9000 family CLI
Cisco Fabric Manager and Device Manager
Quick Configuration Wizard
Cisco Fabric Manager Server (optional; requires Cisco Fabric Manager Server license)
|
|
Software
|
|
Minimum software requirement
|
Cisco MDS 9000 SAN-OS Software Release 3.2(1)
|
|
Compatibility
|
|
Fibre Channel protocols
|
FC-PH, Revision 4.3 (ANSI/INCITS 230-1994)
FC-PH, Amendment 1 (ANSI/INCITS 230-1994/AM1 1996)
FC-PH, Amendment 2 (ANSI/INCITS 230-1994/AM2-1999)
FC-PH-2, Revision 7.4 (ANSI/INCITS 297-1997)
FC-PH-3, Revision 9.4 (ANSI/INCITS 303-1998)
FC-PI, Revision 13 (ANSI/INCITS 352-2002)
FC-PI-2, Revision 10 (ANSI/INCITS 404-2006)
FC-FS, Revision 1.9 (ANSI/INCITS 373-2003)
FC-FS-2, Revision 0.91
FC-LS, Revision 1.2
FC-AL, Revision 4.5 (ANSI/INCITS 272-1996)
FC-AL-2, Revision 7.0 (ANSI/INCITS 332-1999)
FC-AL-2, Amendment 1 (ANSI/INCITS 332-1999/AM1-2003)
FC-AL-2, Amendment 2 (ANSI/INCITS 332-1999/AM2-2006)
FC-SW-2, Revision 5.3 (ANSI/INCITS 355-2001)
FC-SW-3, Revision 6.6 (ANSI/INCITS 384-2004)
FC-SW-4, Revision 7.5 (ANSI/INCITS 418-2006)
FC-GS-3, Revision 7.01 (ANSI/INCITS 348-2001)
FC-GS-4, Revision 7.91 (ANSI/INCITS 387-2004)
FC-GS-5, Revision 8.2
FC-BB, Revision 4.7 (ANSI/INCITS 342-2001)
FC-BB-2, Revision 6.0 (ANSI/INCITS 372-2003)
FC-BB-3, Revision 6.8 (ANSI/INCITS 414-2006)
FCP, Revision 12 (ANSI/INCITS 269-1996)
FCP-2, Revision 8 (ANSI/INCITS 350-2003)
FCP-3, Revision 4 (ANSI/INCITS 416-2006)
FC-SB-2, Revision 2.1 (ANSI/INCITS 349-2001)
FC-SB-3, Revision 1.6 (ANSI/INCITS 374-2003)
FC-VI, Revision 1.84 (ANSI/INCITS 357-2002)
FC-FLA, Revision 2.7 (INCITS TR-20-1998)
FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
FC-Tape, Revision 1.17 (INCITS TR-24-1999)
FC-MI, Revision 1.92 (INCITS TR-30-2002)
FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
FC-SP, Revision 1.6
FC-DA, Revision 3.1 (INCITS TR-36-2004)
FAIS Revision 0.7
Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs
Class of service: Classes 2, 3, and F
Fibre Channel standard port types: E, F, and FL
Fibre Channel enhanced port types: SD, and TE
|
|
Diagnostics and Troubleshooting Tools
|
|
Tools
|
Power-on self-test (POST) diagnostics
Online diagnostics
Internal loopbacks
SPAN
Fibre Channel Traceroute
Fibre Channel Ping
Fibre Channel Debug
Cisco Fabric Analyzer
Syslog
Port-level statistics
|
|
Availability and Serviceability
|
|
Availability
|
Nondisruptive software upgrades
Stateful process restart
Per-VSAN fabric services
Redundant, hot-swappable power supply and fans
Hot-swappable SFP optics
PortChannels aggregating up to 16 ports
Online diagnostics
|
|
|
Serviceability
|
Configuration file management
Port beaconing
System LEDs
SNMP traps for alerts
|
|
Environmental
|
|
Ambient operating temperature
|
32 to 104°F (0 to 40°C)
|
|
|
Ambient non-operating temperature
|
-40 to 158°F (-40 to 70°C)
|
|
|
Physical dimensions
|
(H x W x D) of 1 RU
1.76 x 17.16 x 18.89 in. (4.47 x 43.59 x 47.98 cm)
|
|
|
Weight
|
Switch with dual power supplies: 20 lb (9 KG)
|
|
Power and Cooling
|
|
Power supplies
|
300W AC (maximum of two per switch)
|
|
|
AC Input
|
100 to 240 VAC nominal (+/-10% for full range)
|
|
|
Frequency
|
50 to 60 Hz nominal (+/-3 Hz for full range)
|
|
|
Power consumption
|
99 W maximum with 0.99A at 100 VAC and 0.45 at 220 VAC
|
|
|
Airflow
|
Front to rear
|
|
Regulations
|
|
Safety
|
UL 60950 -1
CAN/CSA-C22.2 No. 60950 -1
EN 60950 -1
IEC 60950 -1
AS/NZS 60950
IEC 60825
EN 60825
21 CFR 1040
|
|
|
EMC
|
FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN55022 Class A
CISPR22 Class A
AS/NZS CISPR22 Class A
VCCI Class A
EN55024
ETS300 386
EN50082-1
EN61000-3-2
EN61000-3-3
EN61000-6-1
CISPR24
NEBS
- GR-63-Core NEBS Level 3
- GR-1089-Core NEBS Level 3
ETSI
- ETS 300 019 Storage Class 1.1
- ETS 300 019 Transportation Class 2.3
- ETSI 300 019 Stationary Use Class 3.1
|
|
Warranty
|
|
Duration
|
1 year
|
|
|
HW coverage hours
|
8 x 8
|
|
|
HW response times
|
4 hours*
*average response times, response times may vary by country
|
|
|
Delivery method
|
On-site
|
|
|
HW phone coverage
|
8 x 8
|