Cisco MDS 9216i Multilayer Fabric Switch

Cisco MDS 9216i Multilayer Fabric Switch

Specifications

No Longer Orderable

Designed for greater flexibility, the Cisco MDS 9216i Multilayer Fabric Switch gives you the benefits of a multiprotocol system without sacrificing Fibre Channel port density. Plus, the expansion slots lets you add additional Fibre Channel or IP ports, providing unparalleled storage services in a single rack unit.


Key Specifications

  • 3-rack unit system supports 14 2 Gb/sec Fibre Channel (FC) ports
  • Expansion slot enables additional Fibre Channel or IP ports
  • Two Gigabit Ethernet ports support FCIP and iSCSI
  • Integrates Fibre Channel and IP storage services in single system
  • High-performance inter-switch links support up to 16 FC links in single PortChannel
Systems Architecture
Port speeds 1, 2 Gb/sec auto-sensing, optionally configurable

Buffer credits Up to 3500 per port

Ports per chassis 14 to 62 Fibre Channel ports, up to 10 1 Gb/sec Ethernet ports

Ports per rack Up to 896

PortChannel Up to 16 physical links

Cards, ports and slots
  • Base: 14 fixed autosensing 1, 2 Gb/sec Fibre Channel ports and 2 fixed 1 Gb/sec Ethernet ports
  • Expansion: 1 empty expansion slot

Fabric services
  • Name server
  • Internet Storage Name Server (iSNS)
  • Registered State Change Notification (RSCN)
  • Login services
  • Fabric Configuration Server (FCS)
  • Private loop
  • Public loop
  • Broadcast
  • In-order delivery

FICON
  • FC-SB-3 compliant
  • Cascaded FICON fabrics
  • Intermix of FICON and Fibre Channel FCP traffic
  • CUP management interface

Advanced functionality
  • VSAN
  • IVR
  • PortChannel with multipath load balancing
  • QoS-flow-based, zone-based
  • Fibre Channel congestion control
  • Extended Buffer-To-Buffer Credits
  • FCIP Write Acceleration
  • FCIP Tape Acceleration

Network security
  • VSANs
  • ACLs
  • Per-VSAN role-based access control
  • Fibre Channel zoning
    • N_Port WWN
    • N_Port FC-ID
    • Fx_Port WWN
    • Fx_Port WWN and interface index
    • Fx_Port domain ID and interface index
    • Fx_Port domain ID and port number
    • LUN
    • Read-only
    • Broadcast
  • iSCSI zoning
    • iSCSI name
    • IP address
  • FC-SP
    • DH-CHAP switch-switch authentication
    • DH-CHAP host-switch authentication
  • Port security and fabric binding
  • IPSec for FCIP and iSCSI
  • IKEv1 and IKEv2
  • Management access
    • SSHv2 implementing AES
    • SNMPv3 implementing AES
  • SFTP
Management
Access methods
  • Out-of-band 10/100 Ethernet port
  • RS-232 serial console port
  • In-band IP over Fibre Channel
  • DB-9 COM port
  • In-band FICON CUP over Fibre Channel

Access protocols
  • CLI-using console and Ethernet ports
  • SNMPv3 via Ethernet port and in-band IP over Fibre Channel access
  • Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
  • FICON CUP

Device alias
  • Distributed Device Alias service

Network security
  • Per-VSAN role-based access control using RADIUS-based and TACACS+-based authentication, authorization, and accounting (AAA) functions SFTP
  • SFTP
  • SSHv2 implementing AES
  • SNMPv3 implementing AES

Management applications
  • Cisco MDS 9000 Family CLI
  • Cisco Fabric Manager
  • Cisco Device Manager
  • CiscoWorks Resource Manager Essentials (RME) and Device Fault Manager (DFM)

Programming interface
  • Scriptable CLI
  • Fabric manager GUI
  • Device manager GUI
Software
Software compatibility Cisco MDS SAN-OS Release 2.0(1) or later
Compatibility
Fibre Channel protocols Fibre Channel standards
  • FC-PH, Revision 4.3 (ANSI/INCITS 230-1994)
  • FC-PH, Amendment 1 (ANSI/INCITS 230-1994/AM1 1996)
  • FC-PH, Amendment 2 (ANSI/INCITS 230-1994/AM2-1999)
  • FC-PH-2, Revision 7.4 (ANSI/INCITS 297-1997)
  • FC-PH-3, Revision 9.4 (ANSI/INCITS 303-1998)
  • FC-PI, Revision 13 (ANSI/INCITS 352-2002)
  • FC-PI-2, Revision 10 (ANSI/INCITS 404-2006)
  • 10GFC, Revision 4.0 (ANSI/INCITS 364:2003)
  • FC-FS, Revision 1.9 (ANSI/INCITS 373-2003)
  • FC-FS-2, Revision 0.92
  • FC-LS, Revision 1.2
  • FC-AL, Revision 4.5 (ANSI/INCITS 272-1996)
  • FC-AL-2, Revision 7.0 (ANSI/INCITS 332-1999)
  • FC-AL-2, Amendment 1 (ANSI/INCITS 332-1999/AM1-2003)
  • FC-AL-2, Amendment 2 (ANSI/INCITS 332-1999/AM2-2006)
  • FC-SW-2, Revision 5.3 (ANSI/INCITS 355-2001)
  • FC-SW-3, Revision 6.6 (ANSI/INCITS 384-2004)
  • FC-SW-4, Revision 7.5 (ANSI/INCITS 418-2006)
  • FC-GS-3, Revision 7.01 (ANSI/INCITS 348-2001)
  • FC-GS-4, Revision 7.91 (ANSI/INCITS 387-2004)
  • FC-GS-5, Revision 8.2
  • FC-BB, Revision 4.7 (ANSI/INCITS 342-2001)
  • FC-BB-2, Revision 6.0 (ANSI/INCITS 372-2003)
  • FC-BB-3, Revision 6.8 (ANSI/INCITS 414-2006)
  • FCP, Revision 12 (ANSI/INCITS 269-1996)
  • FCP-2, Revision 8 (ANSI/INCITS 350-2003)
  • FCP-3, Revision 4 (ANSI/INCITS 416-2006)
  • FC-SB-2, Revision 2.1 (ANSI/INCITS 349-2001)
  • FC-SB-3, Revision 1.6 (ANSI/INCITS 374-2003)
  • FC-VI, Revision 1.84 (ANSI/INCITS 357-2002)
  • FC-FLA, Revision 2.7 (INCITS TR-20-1998)
  • FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
  • FC-Tape, Revision 1.17 (INCITS TR-24-1999)
  • FC-MI, Revision 1.92 (INCITS TR-30-2002)
  • FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
  • FC-SP, Revision 1.74
  • FC-DA, Revision 3.1 (INCITS TR-36-2004)
  • FAIS, Revision 0.7
IP over Fibre Channel (RFC 2625)
IPv6, IPv4 and ARP over FC (RFC 4338)
Extensive IETF-standards based TCP/IP, SNMPv3, and remote monitoring (RMON) MIBs
Class of Service: Class 2, Class 3, Class F
Fibre Channel standard port types: E, F, FL, B
Fibre Channel enhanced port types: SD, ST, TE

IP standards
  • RFC 791 IPv4
  • RFC 793, 1323 TCP
  • RFC 894 IP/Ethernet
  • RFC 1041 IP/802
  • RFC 792, 950, 1256 ICMP
  • RFC 1323 TCP performance enhancements
  • RFC 2338 VRRP
  • RFC 2460, 4291 IPv6
  • RFC 2463 ICMPv6
  • RFC 2461, 2462 IPv6 neighbor discovery and stateless auto-configuration
  • RFC 2464 IPv6/Ethernet
  • RFC 3270 iSCSI
  • RFC 3643, 3821 FCIP

Ethernet standards
  • IEEE 802.3z Gigabit Ethernet
  • IEEE 802.1Q VLAN

IPSec
  • RFC 2401 security architecture for IP
  • RFC 2403, 2404 HMAC
  • RFC 2405, 2406, 2451 IP ESP
  • RFC 2407, 2408 ISAKMP
  • RFC 2412 OAKLEY Key Determination Protocol
  • RFC 3566, 3602, 3686 AES

Internet Key Exchange (IKE)
  • RFC 2409 IKEv1
  • IKEv2, draft
Diagnostics and Troubleshooting Tools
Tools
  • POST diagnostics
  • Online diagnostics
  • Internal port loopbacks
  • SPAN and Remote SPAN
  • Fibre Channel Traceroute
  • Fibre Channel Ping
  • Fibre Channel Debug
  • Cisco Fabric Analyzer
  • Syslog
  • Online system health
  • Port-level statistics
  • Real-Time Protocol Debug
RAS Features
Reliability and availability
  • Hot-swappable, 1+1 redundant power supplies
  • Hot-swappable fan tray with integrated temperature and power management
  • Hot-swappable SFP optics
  • Hot-swappable switching module
  • Passive backplane
  • Stateful process restart
  • Any module, any port configuration for PortChannels
  • Fabric-based multipathing
  • Per-VSAN fabric services
  • Port tracking
  • Virtual Routing Redundancy Protocol (VRRP) for management and FCIP or iSCSI connections
  • Online diagnostics

Serviceability
  • Configuration file management
  • Call Home
  • Power-management LEDs
  • Port beaconing
  • System LED
  • SNMP traps for alerts
  • Network boot
Environmental
Ambient operating temperature 32 to 104°F (0 to 40°C)

Ambient non-operating temperature 40 to 158°F (-40 to 75°C)

Relative humidity, ambient (non-condensing) operating 10 to 90%

Relative humidity, ambient (non-condensing) non-operating and storage 10 to 95%

Altitude, operating -197 to 6500 ft (-60 to 2000 m)

Physical dimensions Dimensions (H x W x D):
5.25 x 17.32 x 22.66 in. (13.34 x 43.99 x 57.56 cm), 3 rack units (RUs)

Weight Fully configured chassis with optional switching module: 70 lb (32 kg)
Power and Cooling
Power supplies
  • 845W AC
  • Input: 100-240V AC (10% range)
  • 50-60 Hz (nominal)

Airflow
  • 200 linear feet per minute (lfm) through system fan assembly
It is recommended that you maintain a minimum air space of 2.5 inches (6.4 cm) between walls and chassis air vents and a minimum horizontal separation of 6 inches (15.2 cm) between two chassis to prevent overheating.
Regulations
Safety CE Marking
UL 60950
CAN/CSA-C22.2 No. 60950
EN 60950
IEC 60950
TS 001
AS/NZS 3260
IEC60825
EN60825
21 CFR 1040

EMC FCC Part 15 (CFR 47) Class A
ICES-003 Class A
EN 55022 Class A
CISPR 22 Class A
AS/NZS 3548 Class A
VCCI Class A
EN 55024
EN 50082-1
EN 61000-6-1
EN 61000-3-2
EN 61000-3-3
Warranty
Duration 2 years

HW coverage hours 24 x 7

HW response times 4 hours*

*average response times, response times may vary by country

Delivery method On-site

HW phone coverage 24 x 7