Tape Drives
|
|
Number of drives
|
LTO 2 – half-height:
One or two
LTO 3 – full height:
One
LTO 3 – half-height:
One or two
LTO 4 – full height:
One
LTO 4 – half-height:
One or two
|
|
|
Drive throughput
|
LTO 2 – half-height:
24 MB/sec
LTO 3 – full height:
80 MB/sec
LTO 3 – half-height:
60 MB/sec
LTO 4 – full height:
120 MB/sec
LTO 4 – half-height:
80 MB/sec
|
|
|
Maximum performance (native)
|
LTO 2 – half-height:
86.4 GB/hr (one drive)
172.8 GB/hr (two drives)
LTO 3 – full height:
288 GB/hr
LTO 3 – half-height:
216 GB/hr (one drive)
432 GB/hr (two drives)
LTO 4 – full height:
432 GB/hr
LTO 4 – half-height:
288 GB/hr (one drive)
576 GB/hr (two drives)
|
|
|
Number of cartridges
|
24
|
|
|
Native capacity
|
LTO 2 – half-height:
4.8 TB
LTO 3 – full height:
9.6 TB
LTO 3 - half-height:
19.2 TB (2 drives)
LTO 4 - full-height:
19.2 TB
LTO 4 - half-height:
38.4 TB (2 drives)
|
|
|
Interface
|
LTO 2 – half-height:
Ultra 160 SCSI LVD
LTO 3 – full height:
Ultra 320 SCSI LVD
4 Gb/sec native FC
LTO 3 – half-height:
Ultra 160 SCSI LVD
3 Gb/sec SAS
LTO 4 – full height:
Ultra 320 SCSI LVD
4 Gb/sec native FC
LTO 4 – half-height:
Ultra 320 SCSI LVD
|
|
Availability
|
|
Mean exchanges/swaps between failure (MEBF/MSBF)
|
2 million robot load/unload cycles
|
|
|
Mean time between failure (MTBF)
|
100,000 hours
|
|
|
Mean time to repair (MTTR)
|
<30 min
|
|
|
Nondisruptive serviceability
|
Hot-swappable drives; Ethernet and
serial ports for diagnostics and reporting
|
|
Compatibility
|
|
Supported host platform
|
Solaris, UNIX, Windows, Linux
|
|
Dimensions
|
|
Out of the box
|
H: 86.5 mm (3.4 in.)
W: 44.5 mm (17.5 in.)
D: 778.5 mm (30.65 in.)
|
|
|
Shipping
|
H: 24.9 mm (9.8 in.)
W: 57.9 mm (22.8 in.)
D: 99.1 mm (39.0 in.)
|
|
Weight
|
|
Out of the box
|
15.6 kg (34.3 lb)
|
|
|
Shipping
|
26.1 kg (57.5 lb)
|
|
Environmental
|
|
Temperature
|
Operating: 5° C to 35° C (41° F to 95° F),
20% to 80% relative humidity, noncondensing
Non-operating: -30° C to 60° C (-22° F to +140° F),
10% to 95% relative humidity, non-condensing
|
|
|
Altitude
|
Operating:
3048 m (10,000 ft)
Non-operating:
10,675 m (35,000 ft)
|
|
|
Power
|
168 W (max)
|
|
|
Input requirements
|
100 to 240 VAC, 50 to 60 Hz, 1.3 to 0.7 Amp
|
|
Regulatory Compliance
|
|
Electromagnetic compatibility
|
FCC (47 CFR 15, Subpart B) Class A;
CE (EN55022 Class A, EN55024, EN61000-3-2, EN61000-3-3);
VCCI (CISPR 22) Class A;
Canada (ICES-003) Class A;
Australia / New Zealand (AS/NZS CISPR22);
Taiwan BSMI (CNS13438 Class A and CNS14336)
|
|
|
Safety
|
UL 60950-1;
CAN/CSA 22.2 No. 60950-1;
EN60950-1
|