Date: 26-Nov-2009   URL: www.sun.com/storage/tape_storage/tape_virtualization/virtual_array/specs.xml

Sun StorageTek V2X2/V2X4f Shared Virtual Array Disk System

Specifications

No Longer Orderable

This product has reached end-of-life and is no longer orderable.

With its advanced virtual technology and near instant capacity-less SnapShot software, the StorageTek V2X2/V2X4f Shared Virtual Array Disk System brings unmatched efficiency into the enterprise. It is the most effective solution for storing, protecting and managing data.


Key Specifications

  • Up to 23.2 TB effective user capacity 96 GB effective user cache capacity
  • Supports mainframe and open systems environments
  • FICON, or ESCON connectivity
Capacity
V2X2 V2X4f
Usable capacity Up to 11.6 TB Up to 23.2 TB

Device images supported 4096 – 3380 J/E/K and/or 3390 1/2/3/Flexvolumes or 1635 – 3390-9 4096 – 3380 J/E/K and/or 3390 1/2/3/Flexvolumes or 2730 – 3390-9 or 834 – 3390-27

Effective user cache capacity Up to 96 GB Up to 96 GB

Drive capacity 73 GB, 15,000 RPM Fibre Channel 146 GB, 15,000 RPM Fibre Channel
Connectivity
V2X2 V2X4f
Ports 4–32 ESCON ports, increments of 2 or 4 4–16 FICON ports, in increments of 2 or 4

Logical paths ESCON: 8,192 (512 per logical control unit) FICON: 2,048 (128 per logical control unit, 256 per FICON port)
Management
V2X2 V2X4f
Storage management Virtual Power Suite including SVA Administrator and SnapVantage software Virtual Power Suite including SVA Administrator and SnapVantage software

Data replication and copy SnapShot, PowerPPRC and PPRC SnapShot copy and remote mirroring software SnapShot, PowerPPRC and PPRC SnapShot copy and remote mirroring software

Backup and migration High Speed Data Mover and Transparent Data Migration Facility software High Speed Data Mover and Transparent Data Migration Facility software

Performance and availability N/A PAV (static and dynamic)
Operating systems support
V2X2 V2X4f
Mainframe OS/390; z/OS; z/VM OS/390; z/OS; z/VM
Mechanical
V2X2 V2X4f
Height 61.0 in (155.0 cm) 61.0 in (155.0 cm)

Depth 30.0 in (77.0 cm) 30.0 in (77.0 cm)

Width 36.0 in (92.0 cm) 36.0 in (92.0 cm)

Weight 982.0 lb (445.0 kg) 982.0 lb (445.0 kg)

Service clearance

Front and rear: 21.3 in (54.1 cm)

Side: 2.5 in (6.4 cm)
Environmental
Relative humidity 20% to 80%

Temperature (operating) +60° to +90° F (+16° to +32° C)

Power KVA 2.6 minimum, 3.8 maximum (dual line cord)

Voltage 200–240 VAC

Frequency 50–60 Hz

Circuit breaker 30 Amps

KBTU per hour 8.6 minimum, 12.4 maximum (dual line cord)
Regulatory compliance
Electromagnetic compatibility FCC (47 CFR 15, Subpart B) Class ACE (EN55022 Class A, EN55024, EN61000-3-2, EN61000-3-3) VCCI (CISPR 22) Class A Canada (ICES-003) Class A

Safety UL 1950; CAN/CSA 22.2 No. 950; EN60950
 
 
Copyright 2004-2009 Sun Microsystems, Inc.